When.com Web Search

  1. Ads

    related to: under sink vent not venting in wall mount toilet carrier parts

Search results

  1. Results From The WOW.Com Content Network
  2. Drain-waste-vent system - Wikipedia

    en.wikipedia.org/wiki/Drain-waste-vent_system

    In-line vent for under-cabinet waste plumbing. In-line vent (also known as an island fixture vent, and, colloquially, a "Chicago Loop", "Boston loop" or "Bow Vent") is an alternate method permissible in some jurisdictions of venting the trap installed on an under counter island sink or other similar applications where a conventional vertical ...

  3. Trap (plumbing) - Wikipedia

    en.wikipedia.org/wiki/Trap_(plumbing)

    The U-bend could not jam, so, unlike the S-bend, it did not need an overflow. In the United States, traps are commonly referred to as P-traps. It is the addition of a 90 degree fitting on the outlet side of a U-bend, thereby creating a P-like shape (oriented horizontally). It is also referred to as a sink trap because it is installed under most ...

  4. Air gap (plumbing) - Wikipedia

    en.wikipedia.org/wiki/Air_gap_(plumbing)

    This "air gap" is visible above the sink as a small cylindrical fixture mounted near the faucet. In the base cabinet under the sink, the drain hose from the dishwasher feeds the "top" of the air gap, and the "bottom" of the air gap is plumbed into the sink drain below the basket, or into a garbage disposal unit. When installed and maintained ...

  5. Gooseneck (piping) - Wikipedia

    en.wikipedia.org/wiki/Gooseneck_(piping)

    Gooseneck vent with check valve being repainted. A gooseneck (or goose neck) is a 180° pipe fitting at the top of a vertical pipe that prevents entry of water. Common implementations of goosenecks are ventilator piping or ducting for bathroom and kitchen exhaust fans, ship holds, landfill methane vent pipes, or any other piping implementation exposed to the weather where water ingress would ...

  6. Heating, ventilation, and air conditioning - Wikipedia

    en.wikipedia.org/wiki/Heating,_ventilation,_and...

    Rooftop HVAC unit with view of fresh-air intake vent Ventilation duct with outlet diffuser vent. These are installed throughout a building to move air in or out of rooms. In the middle is a damper to open and close the vent to allow more or less air to enter the space. The control circuit in a household HVAC installation.

  7. Ventilation (architecture) - Wikipedia

    en.wikipedia.org/wiki/Ventilation_(architecture)

    Ventilation should be considered for its relationship to "venting" for appliances and combustion equipment such as water heaters, furnaces, boilers, and wood stoves. Most importantly, building ventilation design must be careful to avoid the backdraft of combustion products from "naturally vented" appliances into the occupied space.

  8. Heat recovery ventilation - Wikipedia

    en.wikipedia.org/wiki/Heat_recovery_ventilation

    Diagramatic operation of a thermal wheel Ljungström Air Preheater by Swedish engineer Fredrik Ljungström (1875–1964). A thermal wheel, also known as a rotary heat exchanger, or rotary air-to-air enthalpy wheel, energy recovery wheel, or heat recovery wheel, is a type of energy recovery heat exchanger positioned within the supply and exhaust air streams of air-handling units or rooftop ...

  9. Demand controlled ventilation - Wikipedia

    en.wikipedia.org/wiki/Demand_controlled_ventilation

    However, such spaces are not always fully occupied; in these cases, energy is wasted as the HVAC system processes more OA than is necessary for the space occupants. [3] Demand control ventilation is an attractive alternative to standard design in these situations because DCV systems only supply the outdoor airflow necessary to serve the ...