Search results

  1. Results From The WOW.Com Content Network
  2. Short circuit ratio (electrical grid) - Wikipedia

    en.wikipedia.org/wiki/Short_circuit_ratio...

    The short circuit ratio (SCR) is an indicator of the strength of a network bus about the rated power of a device and is frequently used as a measure of system strength. A higher SCR value indicates a stronger system, meaning that the impact of disturbances on voltage and other variables will be minimized.

  3. Short circuit ratio - Wikipedia

    en.wikipedia.org/wiki/Short_circuit_ratio

    Short circuit ratio (or SCR) has multiple meanings: Short circuit ratio (synchronous generator) , a value used to characterize the stability of an electromechanical generator Short circuit ratio (electrical grid) , a metric to characterize the grid strength ("stiffness").

  4. Short circuit ratio (synchronous generator) - Wikipedia

    en.wikipedia.org/wiki/Short_circuit_ratio...

    In a synchronous generator, [1] the short circuit ratio is the ratio of field current required to produce rated armature voltage at the open circuit to the field current required to produce the rated armature current at short circuit. [1] [2] This ratio can also be expressed as an inverse of the saturated [3] direct-axis synchronous reactance ...

  5. Synchronous impedance curve - Wikipedia

    en.wikipedia.org/wiki/Synchronous_impedance_curve

    Synchronous impedance curve (short-circuit characteristic curve), showing armature current as function of field current. The curve is obtained by rotating the generator at the rated RPM with the output terminals shorted and the output current going to 100% of the rated for the device (higher values are typically not tested to avoid overheating).

  6. Short circuit - Wikipedia

    en.wikipedia.org/wiki/Short_circuit

    A short circuit is an abnormal connection between two nodes of an electric circuit intended to be at different voltages. This results in an electric current limited only by the Thévenin equivalent resistance of the rest of the network which can cause circuit damage, overheating, fire or explosion.

  7. Reflections of signals on conducting lines - Wikipedia

    en.wikipedia.org/wiki/Reflections_of_signals_on...

    The special cases of open circuit and short circuit lines are of particular relevance to stubs. Reflections cause standing waves to be set up on the line. Conversely, standing waves are an indication that reflections are present. There is a relationship between the measures of reflection coefficient and standing wave ratio.

  8. Reactances of synchronous machines - Wikipedia

    en.wikipedia.org/wiki/Reactances_of_synchronous...

    Usually applied for transients after a short circuit current. Three states are considered: [5] the steady-state is the normal operating condition with the armature magnetic flux going through the rotor; the sub-transient state (″) is the one the generator enters immediately after the fault (short circuit). In this state the armature flux is ...

  9. Short-circuit test - Wikipedia

    en.wikipedia.org/wiki/Short-circuit_test

    A different form of short-circuit testing is done to assess the mechanical strength of the transformer windings, and their ability to withstand the high forces produced if an energized transformer experiences a short-circuit fault. Currents during such events can be several times the normal rated current.