Leakage inductance derives from the electrical property of an imperfectly coupled transformer whereby each winding behaves as a self-inductance in series with the winding's respective ohmic resistance constant. These four winding constants also interact with the transformer's mutual inductance. The winding leakage inductance is due to leakage ...
Copper loss is the term often given to heat produced by electrical currents in the conductors of transformer windings, or other electrical devices. Copper losses are an undesirable transfer of energy, as are core losses, which result from induced currents in adjacent components.
In contrast to the parallel shunt component, the series component in the circuit diagram represents the winding losses due to the resistance of the coil windings of the transformer. Current, voltage and power are measured at the primary winding to ascertain the admittance and power-factor angle.
The distance between conductors of the transformer forms a capacitance. Any movement of the conductors or windings will change this capacitance. This capacitance being a part of complex L (inductance), R (Resistance) and C (Capacitance) network, any change in this capacitance will be reflected in the curve or signature. [1]
The field produced by a single-phase winding can provide energy to a motor already rotating, but without auxiliary mechanisms the motor will not accelerate from a stop. A rotating magnetic field of steady amplitude requires that all three phase currents be equal in magnitude, and accurately displaced one-third of a cycle in phase.
Per-unit quantities are the same on either side of a transformer, independent of voltage level; By normalizing quantities to a common base, both hand and automatic calculations are simplified. It improves numerical stability of automatic calculation methods. Per unit data representation yields important information about relative magnitudes.
For a transformer with a separate primary and secondary winding, each winding is a portion. For a transformer with interleaved (or sectionalised) windings, the innermost and outermost sections are each one portion, while the other sections are each divided into two portions at the point where zero m.m.f occurs.
The transformer, its windings and all things are distributed symmetrically about the axis of symmetry. The windings are such that there is no circumferential current. The requirements are met for full internal confinement of the B field due to the primary current. The core and primary winding are represented by the gray-brown torus.