When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Volumetric flow rate - Wikipedia

    en.wikipedia.org/wiki/Volumetric_flow_rate

    The SI unit is cubic metres per second (m 3 /s). Another unit used is standard cubic centimetres per minute (SCCM). In US customary units and imperial units, volumetric flow rate is often expressed as cubic feet per second (ft 3 /s) or gallons per minute (either US or imperial definitions).

  3. Standard cubic feet per minute - Wikipedia

    en.wikipedia.org/wiki/Standard_cubic_feet_per_minute

    Cubic feet per minute (CFM) is an often confusing term because it has no single definition that applies to all instances. Gases are compressible , which means that a figure in cubic feet per minute cannot necessarily be compared with another figure when it comes the mass of the gas.

  4. Standard cubic foot - Wikipedia

    en.wikipedia.org/wiki/Standard_cubic_foot

    This regulation defines a standard cubic foot, for compressed or liquefied gases in refillable cylinders other than LPG by, "A standard cubic foot of gas is defined as a cubic foot at a temperature of 21 °C (70 °F) and a pressure of 101.325 kilopascals [kPa] (14.696 psia)".

  5. List of conversion factors - Wikipedia

    en.wikipedia.org/wiki/List_of_conversion_factors

    cubic foot per minute CFM [citation needed] ≡ 1 ft 3 /min = 4.719 474 432 × 10 −4 m 3 /s: cubic foot per second ft 3 /s ≡ 1 ft 3 /s = 0.028 316 846 592 m 3 /s: cubic inch per minute in 3 /min ≡ 1 in 3 /min = 2.731 177 3 × 10 −7 m 3 /s cubic inch per second in 3 /s ≡ 1 in 3 /s = 1.638 7064 × 10 −5 m 3 /s: cubic metre per second ...

  6. Conversion of units - Wikipedia

    en.wikipedia.org/wiki/Conversion_of_units

    = 10 parts per million by volume = 10 ppmv = 10 volumes/10 6 volumes NO x molar mass = 46 kg/kmol = 46 g/mol Flow rate of flue gas = 20 cubic metres per minute = 20 m 3 /min The flue gas exits the furnace at 0 °C temperature and 101.325 kPa absolute pressure. The molar volume of a gas at 0 °C temperature and 101.325 kPa is 22.414 m 3 /kmol.

  7. Flow measurement - Wikipedia

    en.wikipedia.org/wiki/Flow_measurement

    References will be made to "actual" flow rate through a meter and "standard" or "base" flow rate through a meter with units such as acm/h (actual cubic meters per hour), sm 3 /sec (standard cubic meters per second), kscm/h (thousand standard cubic meters per hour), LFM (linear feet per minute), or MMSCFD (million standard cubic feet per day).

  8. Flow coefficient - Wikipedia

    en.wikipedia.org/wiki/Flow_coefficient

    With C v = 1.0 and 200 psia inlet pressure, the flow is 100 standard cubic feet per minute (scfm). The flow is proportional to the absolute inlet pressure, so the flow in scfm would equal the C v flow coefficient if the inlet pressure were reduced to 2 psia and the outlet were connected to a vacuum with less than 1 psi absolute pressure (1.0 ...

  9. Cubic foot - Wikipedia

    en.wikipedia.org/wiki/Cubic_foot

    The IEEE symbol for the cubic foot per second is ft 3 /s. [1] The following other abbreviations are also sometimes used: ft 3 /sec; cu ft/s; cfs or CFS; cusec; second-feet; The flow or discharge of rivers, i.e., the volume of water passing a location per unit of time, is commonly expressed in units of cubic feet per second or cubic metres per second.