Search results
Results From The WOW.Com Content Network
A delta-wye transformer is a type of three-phase electric power transformer design that employs delta-connected windings on its primary and wye/star connected windings on its secondary. A neutral wire can be provided on wye output side. It can be a single three-phase transformer, or built from three independent single-phase units. An equivalent ...
A "delta" (Δ) connected transformer winding is connected between phases of a three-phase system. A "wye" (Y) transformer connects each winding from a phase wire to a common neutral point. A single three-phase transformer can be used, or three single-phase transformers. In an "open delta" or "V" system, only two transformers are used.
A three-phase system may be arranged in delta (∆) or star (Y) (also denoted as wye in some areas, as symbolically it is similar to the letter 'Y'). A wye system allows the use of two different voltages from all three phases , such as a 230/400 V system which provides 230 V between the neutral (centre hub) and any one of the phases, and 400 V ...
For example, a transformer with a vector group of Dy1 has a delta-connected HV winding and a wye-connected LV winding. The phase angle of the LV winding lags the HV by 30 degrees. Note that the high-voltage (HV) side always comes before the low-voltage (LV) side, regardless of which is the primary winding.
delta-wye transformer One type of connection of a three-phase transformer. demand factor The fraction of actual use of some quantity, related to the maximum that could be used in a specified time. demand response The ability of a generating station or grid to follow changes in load while maintaining voltage and frequency within acceptable limits.
In circuit design, the Y-Δ transform, also written wye-delta and also known by many other names, is a mathematical technique to simplify the analysis of an electrical network. The name derives from the shapes of the circuit diagrams , which look respectively like the letter Y and the Greek capital letter Δ .
If a winding is connected to earth , the earth connection point is usually the center point of a wye winding. If the secondary is a delta winding, the ground may be connected to a center tap on one winding (high leg delta) or one phase may be grounded (corner grounded delta).
In three phase power circuits, three phase sources and loads can be connected in two different ways, called a "delta" connection and a "wye" connection. In analyzing circuits, sometimes it simplifies the analysis to convert between equivalent wye and delta circuits. This can be done with the wye-delta transform.