When.com Web Search

  1. Ads

    related to: annual fire pump performance test elevation chart
    • Contact Us

      First in Customer Support

      Speak to a Specialist Now

    • Testimonials

      Hear What Our Customers Have to Say

      Retaining Customers for Life

Search results

  1. Results From The WOW.Com Content Network
  2. Net positive suction head - Wikipedia

    en.wikipedia.org/wiki/Net_positive_suction_head

    If an NPSH A is say 10 bar then the pump you are using will deliver exactly 10 bar more over the entire operational curve of a pump than its listed operational curve. Example: A pump with a max. pressure head of 8 bar (80 metres) will actually run at 18 bar if the NPSH A is 10 bar. i.e.: 8 bar (pump curve) plus 10 bar NPSH A = 18 bar.

  3. Fire pump - Wikipedia

    en.wikipedia.org/wiki/Fire_pump

    A fire pump is a centrifugal-or positive displacement-pump that has been tested and listed by a third-party testing and listing agency, such as UL or FM Global specifically for fire service use. The main standard that governs fire pump fixed-place installations in North America is the National Fire Protection Association 's NFPA 20 Standard for ...

  4. Hydraulic calculation - Wikipedia

    en.wikipedia.org/wiki/Hydraulic_calculation

    The probable intensity and extent of a fire inside the building are indicated by factors including the building use, the building height, the items contained inside the building and their arrangement. These variables are compared to tables and values expressed in the model codes. The values in these tables are based on fire tests and loss history.

  5. Thermodynamic pump testing - Wikipedia

    en.wikipedia.org/wiki/Thermodynamic_pump_testing

    Thermodynamic pump testing is a form of pump testing where only the temperature rise, power consumed, and differential pressure need to be measured to find the efficiency of a pump. These measurements are typically made with insertion temperature probes and pressure probes fitted to tapping points on the pump's inlet and outlet. [ 1 ]

  6. Affinity laws - Wikipedia

    en.wikipedia.org/wiki/Affinity_laws

    The affinity laws (also known as the "Fan Laws" or "Pump Laws") for pumps/fans are used in hydraulics, hydronics and/or HVAC to express the relationship between variables involved in pump or fan performance (such as head, volumetric flow rate, shaft speed) and power. They apply to pumps, fans, and hydraulic turbines. In these rotary implements ...

  7. Comparison of pumps - Wikipedia

    en.wikipedia.org/wiki/Comparison_of_pumps

    Different types of pumps are suitable for different applications, for example: a pump's maximum lift height also determines the applications it can be used for. Low-lift pumps are only suitable for the pumping of surface water (e.g., irrigation, drainage of lands, ...), while high-lift pumps allow deep water pumping (e.g., potable water pumping ...

  8. Fire test - Wikipedia

    en.wikipedia.org/wiki/Fire_test

    A fire test is a means of determining whether fire protection products meet minimum performance criteria as set out in a building code or other applicable legislation. Successful tests in laboratories holding national accreditation for testing and certification result in the issuance of a certification listing .

  9. Fire-resistance rating - Wikipedia

    en.wikipedia.org/wiki/Fire-resistance_rating

    The completed test sample is inserted into a furnace such that one side is exposed to a fire. The test is terminated when the fire stops successfully meet the test criteria in minimizing the amount of heat and smoke allowed to pass through the assembly, when the fire penetrates the fire stops. This determines the fire stop F-Rating.