In many cases, pressure transmitters and primary elements are bought by the end-users from different suppliers. However, several vendors have integrated the pressure transmitter with the primary element to form a complete flowmeter. The advantage of this is that they can be calibrated with the primary element and DP transmitter already in place ...
A rising pressure in the vessel results in the PCV opening to feed more gas forward. If the pressure continues to rise some controllers then act to open a second PCV that feeds excess gas to the flare system. The pressure transmitter is configured to provide warning alarms (PAL and PAH) if the pressure exceeds set high and low limits.
The pressure transmitter modulates the current on the loop to send the signal to the strip chart recorder, but does not in itself supply power to the loop and so is passive. Another loop may contain two passive chart recorders, a passive pressure transmitter, and a 24 V battery (the battery is the active device).
A dead weight tester (DWT) is a calibration standard method that uses a piston cylinder on which a load is placed to make an equilibrium with an applied pressure underneath the piston. Deadweight testers are secondary standards which means that the pressure measured by a deadweight tester is defined through other quantities: length, mass and ...
The Dall tube is a shortened version of a Venturi meter, with a lower pressure drop than an orifice plate. As with these flowmeters the flow rate in a Dall tube is determined by measuring the pressure drop caused by restriction in the conduit. The pressure differential is typically measured using diaphragm pressure transducers with digital readout.
The pneumatic load cell is designed to automatically regulate the balancing pressure. Air pressure is applied to one end of the diaphragm and it escapes through the nozzle placed at the bottom of the load cell. A pressure gauge is attached to the load cell to measure the pressure inside the cell.
In the cgs system the unit of pressure was the barye (ba), equal to 1 dyn·cm −2. In the mts system, the unit of pressure was the pieze, equal to 1 sthene per square metre. Many other hybrid units are used such as mmHg/cm 2 or grams-force/cm 2 (sometimes as kg/cm 2 without properly identifying the force units). Using the names kilogram, gram ...