  1. Results From The WOW.Com Content Network
  2. Electric power distribution - Wikipedia

    en.wikipedia.org/wiki/Electric_power_distribution

    Transformers are typically sized on an average load of 1 to 2 kW per household, and the service fuses and cable is sized to allow any one property to draw a peak load of perhaps ten times this. For industrial customers, 3-phase 690 / 400 volt is also available, or may be generated locally. [19]

  3. Electric power transmission - Wikipedia

    en.wikipedia.org/wiki/Electric_power_transmission

    Voltage was stepped down to 100 volts using the Stanley transformer to power incandescent lamps at 23 businesses over 4,000 feet (1,200 m). [12] This practical demonstration of a transformer and alternating current lighting system led Westinghouse to begin installing AC systems later that year. [11] In 1888 the first designs for an AC motor ...

  4. Mathematics of three-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Mathematics_of_three-phase...

    A three-phase transformer is also shown. Elementary six-wire three-phase alternator, with each phase using a separate pair of transmission wires. Elementary three-wire three-phase alternator, showing how the phases can share only three transmission wires.

  5. Per-unit system - Wikipedia

    en.wikipedia.org/wiki/Per-unit_system

    By choosing the base quantities in this manner, the transformer can be effectively removed from the circuit as described above. For example: Take a transformer that is rated at 10 kVA and 240/100 V. The secondary side has an impedance equal to 1∠0° Ω. The base impedance on the secondary side is equal to:

  6. Split-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Split-phase_electric_power

    A transformer supplying a three-wire distribution system has a single-phase input (primary) winding. The output (secondary) winding has a center tap connected to a grounded neutral. As shown in Fig. 1, either end to center has half the voltage of end-to-end. Fig. 2 illustrates the phasor diagram

  7. Distribution transformer - Wikipedia

    en.wikipedia.org/wiki/Distribution_transformer

    A "transformer bank", widely used in North America: three single-phase transformers connected to make a 3-phase transformer. The low-voltage secondary windings are attached to three or four terminals on the transformer's side. In North American residences and small businesses, the secondary is often the split-phase 120/240-volt system. The 240 ...

  8. Three-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Three-phase_electric_power

    A "delta" (Δ) connected transformer winding is connected between phases of a three-phase system. A "wye" (Y) transformer connects each winding from a phase wire to a common neutral point. A single three-phase transformer can be used, or three single-phase transformers. In an "open delta" or "V" system, only two transformers are used.

  9. Zigzag transformer - Wikipedia

    en.wikipedia.org/wiki/Zigzag_transformer

    A conventional six-winding, grounding transformer or zigzag bank, [1] with the same winding and core quantity as a conventional three-phase transformer, can also be used in zigzag winding connection. In all cases the first coil on each zigzag winding core is connected contrariwise to the second coil on the next core.