When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Hydronics - Wikipedia

    en.wikipedia.org/wiki/Hydronics

    The two-pipe reverse return configuration which is sometimes called 'the three-pipe system' is different from the two-pipe system in the way that water returns to the boiler. In a two-pipe system, once the water has left the first radiator, it returns to the boiler to be reheated, and so with the second and third etc.

  3. Piping and instrumentation diagram - Wikipedia

    en.wikipedia.org/wiki/Piping_and_instrumentation...

    Piping and instrumentation diagram of pump with storage tank. Symbols according to EN ISO 10628 and EN 62424. A more complex example of a P&ID. A piping and instrumentation diagram (P&ID) is defined as follows: A diagram which shows the interconnection of process equipment and the instrumentation used to control the process.

  4. Pipe network analysis - Wikipedia

    en.wikipedia.org/wiki/Pipe_network_analysis

    In fluid dynamics, pipe network analysis is the analysis of the fluid flow through a hydraulics network, containing several or many interconnected branches. The aim is to determine the flow rates and pressure drops in the individual sections of the network.

  5. Central heating - Wikipedia

    en.wikipedia.org/wiki/Central_heating

    Circulating hot water can be used for central heating. Sometimes these systems are called hydronic heating systems. [22] Common components of a central heating system using water-circulation include: A supply of fuel, electric power or district heating supply lines; A boiler (or a heat exchanger for district heating) which heats water in the system

  6. Hydronic balancing - Wikipedia

    en.wikipedia.org/wiki/Hydronic_balancing

    Hydronic balancing, also called hydraulic balancing, is the process of optimizing the distribution of water in a building's hydronic heating or cooling system by equalizing the system pressure. In a balanced system every radiator is set to receive the proper amount of fluid in order to provide the intended indoor climate at optimum energy ...

  7. Zone valve - Wikipedia

    en.wikipedia.org/wiki/Zone_valve

    A zone valve is a specific type of valve used to control the flow of water or steam in a hydronic heating or cooling system.. In the interest of improving efficiency and occupant comfort, such systems are commonly divided up into multiple zones. [1]

  8. Fan coil unit - Wikipedia

    en.wikipedia.org/wiki/Fan_coil_unit

    Hydronic fan coil units can be generally divided into two types: Two-pipe fan coil units or four-pipe fan coil units. Two-pipe fan coil units have one supply and one return pipe. The supply pipe supplies either cold or hot water to the unit depending on the time of year. Four-pipe fan coil units have two supply pipes and two return pipes.

  9. Automatic balancing valve - Wikipedia

    en.wikipedia.org/wiki/Automatic_balancing_valve

    In a variable primary chilled-water system, the design flow rate is determined by the water flow velocity in the tube of the coils. At typical conditions, 6–7 feet per second (1.8–2.1 m/s) Maximum 12 ft/s (3.7 m/s) Minimum 1.5 ft/s (0.46 m/s) (based on a Reynolds number of 7500) Minimum flow is typically 50% or less of the design flow. [1]