When.com Web Search

  1. Ads

    related to: gas furnace valve not opening

Search results

  1. Results From The WOW.Com Content Network
  2. Pilot light - Wikipedia

    en.wikipedia.org/wiki/Pilot_light

    Other units use a non-electrical approach, where the pilot heats a bimetallic element or a gas-filled tube to exert mechanical pressure to keep the gas valve open. If the pilot fails, the valve closes. To restart the system, the valve must be held open manually and the pilot lit, and then the valve must be held open until the element heats up ...

  3. Thermal expansion valve - Wikipedia

    en.wikipedia.org/wiki/Thermal_expansion_valve

    A thermal expansion valve or thermostatic expansion valve (often abbreviated as TEV, TXV, or TX valve) is a component in vapor-compression refrigeration and air conditioning systems that controls the amount of refrigerant released into the evaporator and is intended to regulate the superheat of the refrigerant that flows out of the evaporator ...

  4. Central heating - Wikipedia

    en.wikipedia.org/wiki/Central_heating

    An expansion tank contains compressed gas, separated from the sealed-system water by a diaphragm. This allows for normal variations of pressure in the system. A safety valve allows water to escape from the system when pressure becomes too high, and a valve can open to replenish water from the normal water supply if the pressure drops too low ...

  5. Pressure regulator - Wikipedia

    en.wikipedia.org/wiki/Pressure_regulator

    The inlet pressure gauge will indicate this pressure. The gas then passes through the normally open pressure control valve orifice and the downstream pressure rises until the valve actuating diaphragm is deflected sufficiently to close the valve, preventing any more gas from entering the low pressure side until the pressure drops again.

  6. Valve actuator - Wikipedia

    en.wikipedia.org/wiki/Valve_actuator

    The blue valve body is visible in-line with the pipe. The valve actuator opens or closes the butterfly disc of the valve based on electrical signals sent to the actuator. Another valve actuator is visible in the background, with windows to indicate the valve position. A valve actuator is the mechanism for opening and closing a valve. Manually ...

  7. Thermostat - Wikipedia

    en.wikipedia.org/wiki/Thermostat

    Open gas valve to ignite main burners; Wait (if furnace is relatively recent) until the heat exchanger is at proper operating temperature before starting main blower fan or circulator pump; Oil Similar to gas, except rather than opening a valve, the furnace will start an oil pump to inject oil into the burner Electric

  1. Ads

    related to: gas furnace valve not opening