When.com Web Search

  1. Ad

    related to: rc beam size

Search results

  1. Results From The WOW.Com Content Network
  2. Reinforced concrete column - Wikipedia

    en.wikipedia.org/wiki/Reinforced_Concrete_Column

    ACI Code 7.10.4.2: For cast-in-place construction, size of spirals shall not be less than 3/8 in. diameter. ACI Code 7.10.4.3: Clear spacing between spirals shall not exceed 3 in., nor be less than 1in. Section 10.9.3 adds an additional lower limit to the amount of spiral reinforcement via the volumetric spiral reinforcement ratio ρ s.

  3. Reinforced concrete - Wikipedia

    en.wikipedia.org/wiki/Reinforced_concrete

    A balanced-reinforced beam is one in which both the compressive and tensile zones reach yielding at the same imposed load on the beam, and the concrete will crush and the tensile steel will yield at the same time. This design criterion is however as risky as over-reinforced concrete, because failure is sudden as the concrete crushes at the same ...

  4. Waffle slab - Wikipedia

    en.wikipedia.org/wiki/Waffle_slab

    The height of the ribs and beams should be 1 ⁄ 25 of the span between columns. [3] The width of the solid area around the column should be 1 ⁄ 8 of the span between columns. Its height should be the same as the ribs. [3] Diagram showing waffle slab rib and Beam Heights rule of thumb formulas.

  5. Concrete cover - Wikipedia

    en.wikipedia.org/wiki/Concrete_cover

    The required concrete cover depends on several factors, including the environmental conditions to which the structure will be exposed, the size of the reinforcing steel, the concrete strength, and the type of structure being constructed. Generally, larger diameter reinforcement bars require more concrete cover than smaller ones.

  6. Grade beam - Wikipedia

    en.wikipedia.org/wiki/Grade_beam

    Grade beam. A grade beam or grade beam footing is a component of a building's foundation. It consists of a reinforced concrete beam that transmits the load from a bearing wall into spaced foundations such as pile caps or caissons. [1] It is used in conditions where the surface soil's load-bearing capacity is less than the anticipated design loads.

  7. T-beam - Wikipedia

    en.wikipedia.org/wiki/T-beam

    Unlike an I-beam, a T-beam lacks a bottom flange, which carries savings in terms of materials, but at the loss of resistance to tensile forces. [5] T- beam designs come in many sizes, lengths and widths to suit where they are to be used (eg highway bridge, underground parking garage) and how they have to resist the tension, compression and shear stresses associated with beam bending in their ...

  8. Concrete slab - Wikipedia

    en.wikipedia.org/wiki/Concrete_slab

    A common type of insulated slab is the beam and block system (mentioned above) which is modified by replacing concrete blocks with expanded polystyrene blocks. [11] This not only allows for better insulation but decreases the weight of slab which has a positive effect on load bearing walls and foundations. Formwork set for concrete pour.

  9. Shear and moment diagram - Wikipedia

    en.wikipedia.org/wiki/Shear_and_moment_diagram

    Shear and Bending moment diagram for a simply supported beam with a concentrated load at mid-span. Shear force and bending moment diagrams are analytical tools used in conjunction with structural analysis to help perform structural design by determining the value of shear forces and bending moments at a given point of a structural element such as a beam.