When.com Web Search

  1. Ads

    related to: power factor capacitor calculator for generator battery replacement

Search results

  1. Results From The WOW.Com Content Network
  2. Load bank - Wikipedia

    en.wikipedia.org/wiki/Load_bank

    A resistive/reactive inductive and/or capacitive load is often required to test solar inverters to ensure solar panels can be stopped from producing electricity in the event of a power outage. The resistive/reactive combination load banks are used to test the engine generator set at its rated power factor. In most cases this is 0.8 power factor ...

  3. Capability curve - Wikipedia

    en.wikipedia.org/wiki/Capability_curve

    The fixed speed wind turbines without a power converter (also known as "Type 1" and "Type 2" [5]) cannot be used for voltage control. They simply absorb the reactive power (like any typical induction machine), so a switched capacitor bank is usually used to correct the power factor to unity. [7] Capability curve of a photovoltaic generator

  4. Power factor - Wikipedia

    en.wikipedia.org/wiki/Power_factor

    The power factor in a single-phase circuit (or balanced three-phase circuit) can be measured with the wattmeter-ammeter-voltmeter method, where the power in watts is divided by the product of measured voltage and current. The power factor of a balanced polyphase circuit is the same as that of any phase. The power factor of an unbalanced ...

  5. Induction generator - Wikipedia

    en.wikipedia.org/wiki/Induction_generator

    Power factor correcting capacitors can be added externally to neutralize a constant amount of the variable reactive excitation current. After starting, an induction generator can use a capacitor bank to produce reactive excitation current, but the isolated power system's voltage and frequency are not self-regulating and destabilize readily.

  6. Capacity factor - Wikipedia

    en.wikipedia.org/wiki/Capacity_factor

    Solar PV and wind turbines have a capacity factor limited by the availability of their "fuel", sunshine and wind respectively. A hydroelectricity plant may have a capacity factor lower than 100% due to restriction or scarcity of water, or its output may be regulated to match the current power need, conserving its stored water for later usage.

  7. Capacitive power supply - Wikipedia

    en.wikipedia.org/wiki/Capacitive_power_supply

    By changing the value of the example in the diagram by a capacitor with a value of 330 nF, a current of approximately 20 mA can be provided, as the reactance of the 330 nF capacitor at 50 Hz calculates to = and applying Ohm's law, that limits the current to . This way up to 48 white LEDs in series can be powered (for example, 3.1 V/20 mA/20000 ...

  8. Ripple (electrical) - Wikipedia

    en.wikipedia.org/wiki/Ripple_(electrical)

    A capacitor input filter (in which the first component is a shunt capacitor) and choke input filter (which has a series choke as the first component) can both reduce ripple, but have opposing effects on voltage and current, and the choice between them depends on the characteristics of the load. Capacitor input filters have poor voltage ...

  9. Peukert's law - Wikipedia

    en.wikipedia.org/wiki/Peukert's_law

    For example, consider a battery with a capacity of 200 Ah at the C 20 rate (C 20 means the 20-hour rate – i.e. the rate that will fully discharge the battery in 20 hours – which in this case is 10 A). If this battery is discharged at 10 A, it will last 20 hours, giving the rated capacity of 200 Ah.