Ad
related to: ferrea valves 5000 vs 6000 btu fan switch for furnace troubleshooting problems
Search results
Results From The WOW.Com Content Network
These motors are sometimes called DC motors, sometimes EC motors and occasionally DC/EC motors. DC stands for direct current and EC stands for electronically commutated.. DC motors allow the speed of the fans within a fan coil unit to be controlled by means of a 0-10 Volt input control signal to the motor/s, the transformers and speed switches associated with AC fan coils are not required.
Older furnaces sometimes relied on gravity instead of a blower to circulate air. [1]Gas-fired forced-air furnaces have a burner in the furnace fueled by natural gas.A blower forces cold air through a heat exchanger and then through duct-work that distributes the hot air through the building. [2]
A condensing gas furnace includes a sealed combustion area, combustion draft inducer and a secondary heat exchanger. The primary gain in efficiency for a condensing gas furnace, as compared to a mid-efficiency forced-air or forced-draft furnace, is the capture of latent heat from the exhaust gases in the secondary heat exchanger.
A control valve is a valve used to control fluid flow by varying the size of the flow passage as directed by a signal from a controller. [1] This enables the direct control of flow rate and the consequential control of process quantities such as pressure, temperature, and liquid level.
A thermal expansion valve or thermostatic expansion valve (often abbreviated as TEV, TXV, or TX valve) is a component in vapor-compression refrigeration and air conditioning systems that controls the amount of refrigerant released into the evaporator and is intended to regulate the superheat of the refrigerant that flows out of the evaporator ...
For vacuum- or pneumatically operated zone valves, the thermostat usually switches the pressure or vacuum on or off, causing a spring-loaded rubber diaphragm or ball valve to move and actuate the valve. [2] Unlike the switch-monitored electrical zone valves, these valves automatically return to the default position without the application of ...
A reversing valve removed from an HVAC heat pump for replacement. A reversing valve is a type of valve and is a component in a heat pump, that changes the direction of refrigerant flow. By reversing the flow of refrigerant, the heat pump refrigeration cycle is changed from cooling to heating or vice versa. This allows a residence or facility to ...
A sail switch, vane switch or flow switch is a mechanical switch that is actuated on or off in response to the flow or non-flow of a fluid such as air or water. [1] A sail switch typically operates through the use of a paddle or a diaphragm which gets displaced due to the force of fluid or air moving past it.