  2. Converting "wet" contact closure to "dry" contact closure

    electronics.stackexchange.com/questions/167538/converting-wet-contact-closure...

    A dry signal is just a contact closure. You can use a 3V relay driven by your 3V signal. If the 3V signal does not have enough current capability to drive a 3V relay directly you will need to add a driver transistor and supply appropriate power for the relay coil. Typically this would involve a transistor, base series resistor, diode across the ...

  3. relay - What is a "dry contact input"? - Electrical Engineering...

    electronics.stackexchange.com/questions/80841

    4. Dry contact means no energy is supplied to the contacts (completely passive and isolated). In order for the DAQ to read it, it needs to have a defined voltage, Either a pull up to the positive supply (logic 1) or pull down resistors to the negative supply (logic 0) or an additional IO. Usually, DAQs have a reference voltage output, you can ...

  4. dry contact control relay - Am I on the right path - Electrical...

    electronics.stackexchange.com/questions/354057/dry-contact-control-relay-am-i...

    dry contact control relay - Am I on the right path. Need help understanding a dry contact control relay. My goal is to cut power to an electronics module ( 100 mA max ) with a contact closure input to the relay. By "contact closure" I mean simply the equivalent of mechanical toggle switch closing. I would need a NC output on the relay to ...

  5. relay - Can SSR outputs be considered dry contacts? - Electrical...

    electronics.stackexchange.com/.../can-ssr-outputs-be-considered-dry-contacts

    This FAQ from Omron discusses certain possible "gotchas" for SSR's which would not generally be encountered with a conventional relay. The SSR could replace in some cases mechanical relays.You should check compatibility. Commutating voltage, load current, contact resistance. Take as an example lh15801 from Vishay.

  6. Trying to understand dry contact relay | All About Circuits

    forum.allaboutcircuits.com/threads/trying-to-understand-dry-contact-relay.140334

    Sep 23, 2017. #2. Go about it methodically. The relay has a coil. Find it and measure the voltage across the coil pins. If you're getting 0V (or close to it) when you close the switch then you have two places to look: whether you are really closing the switch via sw or the driver circuit isn't working. Like.

  7. Recommended voltage/current for dry contact input?

    electronics.stackexchange.com/questions/91973/recommended-voltage-current-for...

    A dry contact can sometimes require what is known as a wetting current. This means that when the contact closes, a current is available to flow through the contact of a certain amount (usually specified by the vendor). This is usually achieved by the load and, in the case of a relay, it might be a few milliamps to several amps.

  8. Understanding relay contact ratings - Electrical Engineering...

    electronics.stackexchange.com/questions/436977/understanding-relay-contact-ratings

    5. I'd think that the two ratings that matter are "rated thermal current" and "rated insulation voltage" which tells the user the maximum voltage/current the relay can withstand. These tell you how much the relay can carry when closed, not how much it can break when opening. You need to look at the 'contacts' section of the data sheet to see ...

  9. Why does a relay have a minimum applicable load?

    electronics.stackexchange.com/questions/214139

    42. The primary reason that almost all relays have a minimum load requirement is that the mechanical action of closing coupled with an actual current flow are required to 'whet' the contact and break through a layer of oxidation that invariably builds up.

  10. Switch multiple contacts in parallel from a single 24V DDC output

    electronics.stackexchange.com/questions/451126/switch-multiple-contacts-in...

    for 100 dry-contact signals buy 25 four-pole relays. (four pole seems to be the best price point) There should be a way to command the 25 relays from a single output. Perhaps wire the coils in parallel and use another higher current relay to switch the current that runs these.

  11. Can I run 2 relays in parallel for dry/wet contacts?

    electronics.stackexchange.com/questions/585263

    The end device (FAN) has 2 terminals that give out 24VAC (SS CMD, wet contact). When SS CMD contacts are jumped/closed, the fan turns on. Does this diagram work for running them in parallel (if either relay is energized, fan turns on)? If G1/C1 energizes and the contact closes, what will happen to G2/C2 contact since the wires are touching ...