  2. Power usage effectiveness - Wikipedia

    en.wikipedia.org/wiki/Power_usage_effectiveness

    As of the end of Q2 2015, Facebook's Prineville data center had a power usage effectiveness (PUE) of 1.078 and its Forest City data center had a PUE of 1.082. [15] In October 2015, Allied Control has a claimed PUE ratio of 1.02 [16] through the use of two-phase immersion cooling using 3M Novec 7100 fluid.

  3. Green Power Usage Effectiveness - Wikipedia

    en.wikipedia.org/.../Green_Power_Usage_Effectiveness

    It is an addition to the power usage effectiveness (PUE) definition and was first proposed by Greenqloud. [1] The Green Grid has developed the Power Usage Effectiveness metric [2] or PUE to measure a data centers' effectiveness of getting power to IT equipment. What the PUE tells in simple terms is how much extra energy is needed for each ...

  4. Data center infrastructure efficiency - Wikipedia

    en.wikipedia.org/wiki/Data_center_infrastructure...

    Data center infrastructure efficiency (DCIE), is a performance improvement metric used to calculate the energy efficiency of a data center. DCIE is the percentage value derived, by dividing information technology equipment power by total facility power. [1] [2] [3]

  5. Green data center - Wikipedia

    en.wikipedia.org/wiki/Green_data_center

    The best PUE a data center can have is 1: an ideal situation, with no extra energy use. When PUE was introduced, studies found that the industry-average PUE was between 2.5 and 3. In more recent studies, the average PUE fell to about 1.7 by using this framework. PUE began the shift of the data-center industry towards energy efficiency. [5]

  6. HP Performance Optimized Datacenter - Wikipedia

    en.wikipedia.org/wiki/HP_Performance_Optimized...

    The perfect efficiency would be a Power usage effectiveness (PUE) of 1.0. [ 11 ] The POD 240a has a refrigerant-based air cooled HVAC system with air-side economization [ 3 ] When the ambient air conditions are cool enough, the 240a uses economizer or free air mode—where outside air can be taken in and circulated inside the modular data ...

  7. HuffPost Data

    data.huffingtonpost.com

    HuffPost Data Visualization, analysis, interactive maps and real-time graphics. Browse, copy and fork our open-source software.; Remix thousands of aggregated polling results.

  8. Performance per watt - Wikipedia

    en.wikipedia.org/wiki/Performance_per_watt

    The power measurement is often the average power used while running the benchmark, but other measures of power usage may be employed (e.g. peak power, idle power). For example, the early UNIVAC I computer performed approximately 0.015 operations per watt-second (performing 1,905 operations per second (OPS), while consuming 125 kW).