When.com Web Search

  1. Ads

    related to: chimney induced draft fan

Search results

  1. Results From The WOW.Com Content Network
  2. Draft (boiler) - Wikipedia

    en.wikipedia.org/wiki/Draft_(boiler)

    Forced draft: When air or flue gases are maintained above atmospheric pressure. Normally it is done with the help of a forced draft fan. [2] Induced draft: When air or flue gases flow under the effect of a gradually decreasing pressure below atmospheric pressure. In this case, the system is said to operate under induced draft.

  3. Stack effect - Wikipedia

    en.wikipedia.org/wiki/Stack_effect

    The draft (draught in British English) flow rate induced by the stack effect can be calculated with the equation presented below. [12] [13] The equation applies only to buildings where air is both inside and outside the buildings. For buildings with one or two floors, h is the height of the building and A is the flow area of the openings.

  4. Cooling tower - Wikipedia

    en.wikipedia.org/wiki/Cooling_tower

    Induced draft – A mechanical draft tower with a fan at the discharge (at the top) which pulls air up through the tower. The fan induces hot moist air out the discharge. This produces low entering and high exiting air velocities, reducing the possibility of recirculation in which discharged air flows back into the air intake.

  5. Flue-gas stack - Wikipedia

    en.wikipedia.org/wiki/Flue-gas_stack

    A flue gas stack at GRES-2 Power Station in Ekibastuz, Kazakhstan, the tallest of its kind in the world (420 meters or 1,380 feet) [1]. A flue-gas stack, also known as a smoke stack, chimney stack or simply as a stack, is a type of chimney, a vertical pipe, channel or similar structure through which flue gases are exhausted to the outside air.

  6. Boiler (power generation) - Wikipedia

    en.wikipedia.org/wiki/Boiler_(power_generation)

    The third method is by simply using an induced draught fan (ID fan) which sucks flue gases out of the furnace and up the stack. Almost all induced draught furnaces have a negative pressure. Forced draught: draught is obtained by forcing air into the furnace by means of a fan (FD fan) and duct-work.

  7. Forced-air gas - Wikipedia

    en.wikipedia.org/wiki/Forced-air_gas

    As a result it can be more easily routed through walls or floors. However, the condensing furnace is more expensive initially because of the extra induced-draft fan and condensate pump required, and the extra heat exchanger in the firebox. The heat exchangers may be damaged by corrosion or metal fatigue from many heating and cooling cycles.