When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Mass flow rate - Wikipedia

    en.wikipedia.org/wiki/Mass_flow_rate

    A correct description of such an object requires the application of Newton's second law to the entire, constant-mass system consisting of both the object and its ejected mass. [7] Mass flow rate can be used to calculate the energy flow rate of a fluid: [8] ˙ = ˙, where is the unit mass energy of a system.

  3. Mass flux - Wikipedia

    en.wikipedia.org/wiki/Mass_flux

    Mathematically, mass flux is defined as the limit =, where = = is the mass current (flow of mass m per unit time t) and A is the area through which the mass flows.. For mass flux as a vector j m, the surface integral of it over a surface S, followed by an integral over the time duration t 1 to t 2, gives the total amount of mass flowing through the surface in that time (t 2 − t 1): = ^.

  4. Standard cubic centimetres per minute - Wikipedia

    en.wikipedia.org/wiki/Standard_cubic_centimetres...

    Standard cubic centimeters per minute (SCCM) is a unit used to quantify the flow rate of a fluid. 1 SCCM is identical to 1 cm³ STP /min. Another expression of it would be Nml/min.

  5. Discharge coefficient - Wikipedia

    en.wikipedia.org/wiki/Discharge_coefficient

    In a nozzle or other constriction, the discharge coefficient (also known as coefficient of discharge or efflux coefficient) is the ratio of the actual discharge to the ideal discharge, [1] i.e., the ratio of the mass flow rate at the discharge end of the nozzle to that of an ideal nozzle which expands an identical working fluid from the same initial conditions to the same exit pressures.

  6. Standard cubic feet per minute - Wikipedia

    en.wikipedia.org/wiki/Standard_cubic_feet_per_minute

    Standard cubic feet per minute (SCFM) is the molar flow rate of a gas expressed as a volumetric flow at a "standardized" temperature and pressure thus representing a fixed number of moles of gas regardless of composition and actual flow conditions. It is related to the mass flow rate of the gas by a multiplicative constant which depends only on ...

  7. Flow measurement - Wikipedia

    en.wikipedia.org/wiki/Flow_measurement

    Energy flow rate is usually derived from mass or volumetric flow rate by the use of a flow computer. In engineering contexts, the volumetric flow rate is usually given the symbol , and the mass flow rate, the symbol ˙. For a fluid having density , mass and volumetric flow rates may be related by ˙ =.

  8. Compressor characteristic - Wikipedia

    en.wikipedia.org/wiki/Compressor_characteristic

    Choking is the condition which occurs in the compressor in which it operates at very high mass flow rate and flow through the compressor can't be further increased as mach number at some part of the compressor reach to unity i.e. to sonic velocity and the flow is said to be choked. In compressor maximum volume flow rate is limited by cross ...

  9. Choked flow - Wikipedia

    en.wikipedia.org/wiki/Choked_flow

    The above equations calculate the steady state mass flow rate for the pressure and temperature existing in the upstream pressure source. If the gas is being released from a closed high-pressure vessel, the above steady state equations may be used to approximate the initial mass flow rate. Subsequently, the mass flow rate decreases during the ...