Search results
Results From The WOW.Com Content Network
A RAID 0 array of n drives provides data read and write transfer rates up to n times as high as the individual drive rates, but with no data redundancy. As a result, RAID 0 is primarily used in applications that require high performance and are able to tolerate lower reliability, such as in scientific computing [5] or gaming.
RAID 01, also called RAID 0+1, is a RAID level using a mirror of stripes, achieving both replication and sharing of data between disks. [3] The usable capacity of a RAID 01 array is the same as in a RAID 1 array made of the same drives, in which one half of the drives is used to mirror the other half.
RAID (/ r eɪ d /; redundant array of inexpensive disks or redundant array of independent disks) [1] [2] is a data storage virtualization technology that combines multiple physical data storage components into one or more logical units for the purposes of data redundancy, performance improvement, or both.
The four-drive example is identical to a standard RAID 1+0 array, while the three-drive example is a software implementation of RAID 1E. The two-drive example is equivalent to RAID 1. [13] The driver also supports a "far" layout, in which all the drives are divided into f sections. All the chunks are repeated in each section but are switched in ...
Linux supports Matrix RAID and Rapid Storage Technology (RST) through device mapper, with dmraid tool, for RAID 0, 1 and 10. And Linux MD RAID, with mdadm tool, for RAID 0, 1, 10, and 5. Set up of the RAID volumes must be done by using the ROM option in the Matrix Storage Manager, then further configuration can be done in DM-RAID or MD-RAID. [10]
If RAID 0 were used, then disk 0 and disk 2 would be truncated to 28 blocks, the size of the smallest disk in the array (disk 1) for a total size of 84 blocks. [citation needed] What makes a SPAN or BIG different from RAID configurations is the possibility for the selection of drives.
When a RAID array experiences the failure of one or more disks, it can enter degraded mode, [1] a fallback mode that generally allows the continued usage of the array, but either loses the performance boosts of the RAID technique (such as a RAID-1 mirror across two disks when one of them fails; performance will fall back to that of a normal ...
RAID stands for redundant array of independent disks (or, formerly, redundant array of inexpensive disks). RAID levels may refer to: Standard RAID levels, all the RAID configurations defined in the Common RAID Disk Drive Format standard, which is maintained by the Storage Networking Industry Association