  2. Underfloor heating - Wikipedia

    en.wikipedia.org/wiki/Underfloor_heating

    However, when the floor covering is known at the time the system is installed, then the internal floor temperature required for a given covering can be achieved through proper tube spacing without sacrificing plant efficiency (though the higher internal floor temperatures may result in increased heat loss from the non-room surfaces of the floor).

  3. Underfloor air distribution - Wikipedia

    en.wikipedia.org/wiki/Underfloor_air_distribution

    The ground floor with a slab on grade has less temperature rise compared to middle and top floors, and an increase of the supply air temperature causes a decrease in the temperature rise. The temperature rise is not significantly affected by the perimeter zone orientation, the internal heat gain and the window-to-wall ratio. [16]

  4. ASHRAE 55 - Wikipedia

    en.wikipedia.org/wiki/ASHRAE_55

    Operative temperature or PMV should be calculated at 0.6 m for seated occupants, 1.1 m for standing occupants, and the mean height of the body for horizontal occupants. [10] Local discomfort caused by floor temperature and radiant temperature asymmetry should be measured at the floor surface and at the occupants’ locations, respectively. [12]

  5. Radiant heating and cooling - Wikipedia

    en.wikipedia.org/wiki/Radiant_heating_and_cooling

    The internal air temperature for radiant heated buildings may be lower than for a conventionally heated building to achieve the same level of body comfort, when adjusted so the perceived temperature is actually the same. One of the key advantages of radiant heating systems is a much decreased circulation of air inside the room and the ...

  6. Cooling load temperature difference calculation method

    en.wikipedia.org/wiki/Cooling_load_temperature...

    The first of the cooling load factors used in this method is the CLTD, or the Cooling Load Temperature Difference. This factor is used to represent the temperature difference between indoor and outdoor air with the inclusion of the heating effects of solar radiation. [1] [5] The second factor is the CLF, or the cooling load factor.

  7. Low emissivity - Wikipedia

    en.wikipedia.org/wiki/Low_emissivity

    Low emissivity (low e or low thermal emissivity) refers to a surface condition that emits low levels of radiant thermal (heat) energy. All materials absorb, reflect, and emit radiant energy according to Planck's law but here, the primary concern is a special wavelength interval of radiant energy, namely thermal radiation of materials. In common ...

  8. Gypsum concrete - Wikipedia

    en.wikipedia.org/wiki/Gypsum_concrete

    Gypsum concrete is a building material used as a floor underlayment used in wood-frame and concrete construction for fire ratings, sound reduction, radiant heating, and floor leveling. [1] It is a mixture of gypsum plaster, Portland cement , and sand .

  9. Radiator (heating) - Wikipedia

    en.wikipedia.org/wiki/Radiator_(heating)

    In underfloor heating, tubing is placed on the floor throughout the room and later covered with a concrete layer during construction. Also known as "radiant heat", underfloor heating uses a network of pipes, tubing or heating cables, buried in or attached beneath a floor to allow heat to rise into the room.