Search results
Results From The WOW.Com Content Network
RAID 0 (also known as a stripe set or striped volume) splits ("stripes") data evenly across two or more disks, without parity information, redundancy, or fault tolerance. Since RAID 0 provides no fault tolerance or redundancy, the failure of one drive will cause the entire array to fail, due to data being striped across all disks.
RAID 01, also called RAID 0+1, is a RAID level using a mirror of stripes, achieving both replication and sharing of data between disks. [3] The usable capacity of a RAID 01 array is the same as in a RAID 1 array made of the same drives, in which one half of the drives is used to mirror the other half.
Those RAID systems made their way to the consumer market, for users wanting the fault-tolerance of RAID without investing in expensive SCSI drives. Fast consumer drives make it possible to build RAID systems at lower cost than with SCSI, but most ATA RAID controllers lack a dedicated buffer or high-performance XOR hardware for parity calculation.
There is a difference between fault tolerance and systems that rarely have problems. For instance, the Western Electric crossbar systems had failure rates of two hours per forty years, and therefore were highly fault resistant. But when a fault did occur they still stopped operating completely, and therefore were not fault tolerant.
A parity drive is a hard drive used in a RAID array to provide fault tolerance. For example, RAID 3 uses a parity drive to create a system that is both fault tolerant and, because of data striping, fast. [1] Basically, a single data bit is added to the end of a data block to ensure the number of bits in the message is either odd or even. [2]
In computing, System Fault Tolerance (SFT) is a fault tolerant system built into NetWare operating systems. Three levels of fault tolerance exist: Three levels of fault tolerance exist: SFT I 'Hot Fix' maps out bad disk blocks on the file system level to help ensure data integrity (fault tolerance on the disk-block level)
The result is increased reliability in a RAID array. In a stand-alone configuration TLER should be disabled. As the drive is not redundant, reporting segments as failed will only increase manual intervention. Without a hardware RAID controller or a software RAID implementation to drop the disk, normal (no TLER) recovery ability is most stable.
RAID (32 P) U. Uninterruptible power supply (7 P, 1 F) Pages in category "Fault-tolerant computer systems" The following 72 pages are in this category, out of 72 total.