When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Flux linkage - Wikipedia

    en.wikipedia.org/wiki/Flux_linkage

    Thus, for a typical inductance (a coil of conducting wire), the flux linkage is equivalent to magnetic flux, which is the total magnetic field passing through the surface (i.e., normal to that surface) formed by a closed conducting loop coil and is determined by the number of turns in the coil and the magnetic field, i.e.,

  3. Coenergy - Wikipedia

    en.wikipedia.org/wiki/Coenergy

    If there is a finite change in flux linkage from one value to another (e.g. from to ), it can be calculated as: = () (If the changes are cyclic there will be losses for hysteresis and eddy currents. The additional energy for this would be taken from the input energy, so that the flux linkage to the coil is not affected by the losses and the ...

  4. Eddy current - Wikipedia

    en.wikipedia.org/wiki/Eddy_current

    This change in magnetic flux, in turn, induces a circular electromotive force (EMF) in the sheet, in accordance with Faraday's law of induction, exerting a force on the electrons in the sheet, causing a counterclockwise circular current in the sheet. This is an eddy current.

  5. Bifilar coil - Wikipedia

    en.wikipedia.org/wiki/Bifilar_coil

    When used in a switching transformer, one winding of the bifilar coil is used as a means of removing the energy stored in the stray magnetic flux which fails to link the primary coil to the secondary coil of the transformer. Because of their proximity, the wires of the bifilar coil both "see" the same stray magnetic flux.

  6. Advection upstream splitting method - Wikipedia

    en.wikipedia.org/wiki/Advection_upstream...

    The AUSM is developed as a numerical inviscid flux function for solving a general system of conservation equations. It is based on the upwind concept and was motivated to provide an alternative approach to other upwind methods, such as the Godunov method , flux difference splitting methods by Roe, and Solomon and Osher, flux vector splitting ...

  7. Magnetic flux - Wikipedia

    en.wikipedia.org/wiki/Magnetic_flux

    In physics, specifically electromagnetism, the magnetic flux through a surface is the surface integral of the normal component of the magnetic field B over that surface. It is usually denoted Φ or Φ B. The SI unit of magnetic flux is the weber (Wb; in derived units, volt–seconds or V⋅s), and the CGS unit is the maxwell. [1]

  8. Direct torque control - Wikipedia

    en.wikipedia.org/wiki/Direct_torque_control

    Direct torque control (DTC) is one method used in variable-frequency drives to control the torque (and thus finally the speed) of three-phase AC electric motors.This involves calculating an estimate of the motor's magnetic flux and torque based on the measured voltage and current of the motor.

  9. Leakage inductance - Wikipedia

    en.wikipedia.org/wiki/Leakage_inductance

    The magnetic circuit's flux that does not interlink both windings is the leakage flux corresponding to primary leakage inductance L P σ and secondary leakage inductance L S σ. Referring to Fig. 1, these leakage inductances are defined in terms of transformer winding open-circuit inductances and associated coupling coefficient or coupling ...