When.com Web Search

  1. Ad

    related to: flux linkage coil set up pdf template excel

Search results

  1. Results From The WOW.Com Content Network
  2. Flux linkage - Wikipedia

    en.wikipedia.org/wiki/Flux_linkage

    Thus, for a typical inductance (a coil of conducting wire), the flux linkage is equivalent to magnetic flux, which is the total magnetic field passing through the surface (i.e., normal to that surface) formed by a closed conducting loop coil and is determined by the number of turns in the coil and the magnetic field, i.e.,

  3. Coenergy - Wikipedia

    en.wikipedia.org/wiki/Coenergy

    If there is a finite change in flux linkage from one value to another (e.g. from to ), it can be calculated as: = () (If the changes are cyclic there will be losses for hysteresis and eddy currents. The additional energy for this would be taken from the input energy, so that the flux linkage to the coil is not affected by the losses and the ...

  4. Armature (electrical) - Wikipedia

    en.wikipedia.org/wiki/Armature_(electrical)

    Armature reaction drop is the effect of a magnetic field on the distribution of the flux under main poles of a generator. [5] Since an armature is wound with coils of wire, a magnetic field is set up in the armature whenever a current flows in the coils.

  5. Henry (unit) - Wikipedia

    en.wikipedia.org/wiki/Henry_(unit)

    The henry (symbol: H) is the unit of electrical inductance in the International System of Units (SI). [1] If a current of 1 ampere flowing through a coil produces flux linkage of 1 weber turn, that coil has a self-inductance of 1 henry.‌ The unit is named after Joseph Henry (1797–1878), the American scientist who discovered electromagnetic induction independently of and at about the same ...

  6. Inductance - Wikipedia

    en.wikipedia.org/wiki/Inductance

    The inductance is proportional to the square of the number of turns in the coil, assuming full flux linkage. The inductance of a coil can be increased by placing a magnetic core of ferromagnetic material in the hole in the center. The magnetic field of the coil magnetizes the material of the core, aligning its magnetic domains, and the magnetic ...

  7. Direct torque control - Wikipedia

    en.wikipedia.org/wiki/Direct_torque_control

    Direct torque control (DTC) is one method used in variable-frequency drives to control the torque (and thus finally the speed) of three-phase AC electric motors.This involves calculating an estimate of the motor's magnetic flux and torque based on the measured voltage and current of the motor.

  8. Vector control (motor) - Wikipedia

    en.wikipedia.org/wiki/Vector_control_(motor)

    In vector control, an AC induction or synchronous motor is controlled under all operating conditions like a separately excited DC motor. [21] That is, the AC motor behaves like a DC motor in which the field flux linkage and armature flux linkage created by the respective field and armature (or torque component) currents are orthogonally aligned such that, when torque is controlled, the field ...

  9. Superconducting magnetic energy storage - Wikipedia

    en.wikipedia.org/wiki/Superconducting_magnetic...

    Here the energy is stored by disconnecting the coil from the larger system and then using electromagnetic induction from the magnet to induce a current in the superconducting coil. This coil then preserves the current until the coil is reconnected to the larger system, after which the coil partly or fully discharges. Refrigeration system