In an electric power system, a fault or fault current is any abnormal electric current. For example, a short circuit is a fault in which a live wire touches a neutral or ground wire. An open-circuit fault occurs if a circuit is interrupted by a failure of a current-carrying wire (phase or neutral) or a blown fuse or circuit breaker.
A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) [a] is an electrical safety device, more specifically a form of Earth-leakage circuit breaker, that interrupts an electrical circuit when the current passing through line and neutral conductors of a circuit is not equal (the term residual relating to the imbalance), therefore ...
Power system protection is a branch of electrical power engineering that deals with the protection of electrical power systems from faults [citation needed] through the disconnection of faulted parts from the rest of the electrical network. The objective of a protection scheme is to keep the power system stable by isolating only the components ...
A problem arises if the electricity supply is upgraded, by adding new generation capacity or by adding cross-connections. Because these increase the amount of power that can be supplied, all of the branch circuits must have their bus bars and circuit breakers upgraded to handle the new higher fault current limit. [citation needed]
Power outages are categorized into three different phenomena, relating to the duration and effect of the outage: A transient fault is a loss of power typically caused by a fault on a power line, e.g. a short circuit or flashover. Power is automatically restored once the fault is cleared. A brownout is a drop in voltage in an electrical power ...
An inrush current limiter is a component used to limit inrush current to avoid gradual damage to components and avoid blowing fuses or tripping circuit breakers.Negative temperature coefficient (NTC) thermistors and fixed resistors are often used to limit inrush current.
Examples of TRV waveshapes. A transient recovery voltage (TRV) for high-voltage circuit breakers is the voltage that appears across the terminals after current interruption. It is a critical parameter for fault interruption by a high-voltage circuit breaker, its characteristics (amplitude, rate of rise) can lead either to a successful current interruption or to a failure (called reignition or ...
In electrical engineering, a protective relay is a relay device designed to trip a circuit breaker when a fault is detected. [ 1 ] : 4 The first protective relays were electromagnetic devices, relying on coils operating on moving parts to provide detection of abnormal operating conditions such as over-current, overvoltage , reverse power flow ...