When.com Web Search

  1. Ads

    related to: kva to amp conversion chart

Search results

  1. Results From The WOW.Com Content Network
  2. Volt-ampere - Wikipedia

    en.wikipedia.org/wiki/Volt-ampere

    Volt-amperes are usually used for analyzing alternating current (AC) circuits. In direct current (DC) circuits, this product is equal to the real power , measured in watts . [ 3 ] The volt-ampere is dimensionally equivalent to the watt : in SI units , 1 V⋅A = 1 W. VA rating is most used for generators and transformers, and other power ...

  3. Orders of magnitude (current) - Wikipedia

    en.wikipedia.org/wiki/Orders_of_magnitude_(current)

    400 V low voltage secondary side distribution transformer with primary 12 kV; 200 kVA (up to 1000 kVA also common) [7] 10 3: 2 kA 10.5 kV secondary side from an electrical substation with primary 115 kV; 63 MVA [8] 9.3 kA 2.7V, Ultracapacitor short circuit current [9] 10 4: 25 kA Lorentz force can crusher pinch [10] 30 kA Typical lightning ...

  4. Per-unit system - Wikipedia

    en.wikipedia.org/wiki/Per-unit_system

    Moreover, similar types of apparatus will have the impedances lying within a narrow numerical range when expressed as a per-unit fraction of the equipment rating, even if the unit size varies widely. Conversion of per-unit quantities to volts, ohms, or amperes requires a knowledge of the base that the per-unit quantities were referenced to.

  5. NEMA size - Wikipedia

    en.wikipedia.org/wiki/NEMA_size

    Main page; Contents; Current events; Random article; About Wikipedia; Contact us; Pages for logged out editors learn more

  6. Rating plate - Wikipedia

    en.wikipedia.org/wiki/Rating_plate

    power rating is specified in terms of apparent power (KVA or MVA), since the exact power factor will be determined by the external factors; [5] power factor (PF) is the nominal power factor for other ratings; usually PF = 0.8; [5] insulation class (B, F, H) for the primary coil. Typical value is F, although older generators might use class B; [5]

  7. Electric power transmission - Wikipedia

    en.wikipedia.org/wiki/Electric_power_transmission

    Should an ideal transformer convert high-voltage, low-current electricity into low-voltage, high-current electricity with a voltage ratio of (i.e., the voltage is divided by and the current is multiplied by in the secondary branch, compared to the primary branch), then the circuit is again equivalent to a voltage divider, but the wires now have ...

  8. Power factor - Wikipedia

    en.wikipedia.org/wiki/Power_factor

    Power factors below 1.0 require a utility to generate more than the minimum volt-amperes necessary to supply the real power (watts). This increases generation and transmission costs. For example, if the load power factor were as low as 0.7, the apparent power would be 1.4 times the real power used by the load.

  9. Split-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Split-phase_electric_power

    Pole-mounted single-phase transformer with three-wire center-tapped "split-phase" secondary. On the three secondary terminals, the center tap is grounded with a short strap to the transformer case.