Search results
Results From The WOW.Com Content Network
In fluid dynamics, total dynamic head (TDH) is the work to be done by a pump, per unit weight, per unit volume of fluid.TDH is the total amount of system pressure, measured in feet, where water can flow through a system before gravity takes over, and is essential for pump specification.
Discharge pressure (also called high side pressure or head pressure) is the pressure generated on the output side of a gas compressor in a refrigeration or air conditioning system. The discharge pressure is affected by several factors: size and speed of the condenser fan, condition and cleanliness of the condenser coil, and the size of the ...
Dry running protection, also known as dry-run protection or dry-running protection, is a type of protection mechanism to prevent a rotor, pump or stirrer shaft from operating without any medium added, as the bearing and shaft seal might be damaged if the motor is run while dry. [1]
Prior to the 1960s, a pressure switch was used in the hydraulic braking circuit to control power to the brake lights; more recent automobiles use a switch directly activated by the brake pedal. In dust control systems (bag filter), a pressure switch is mounted on the header which will raise an alarm when air pressure in the header is less than ...
This is a crucial parameter for pump selection and is a popularly used parameter for ascertaining industrial requirements. By eliminating the inlet head, we remove the effect of the supplied pressure to the pump and are left with only the pump’s energy (head) contribution to the fluid flow. Schematic representation of pressure heads in a pump.
The total hydraulic head of a fluid is composed of pressure head and elevation head. [1] [2] The pressure head is the equivalent gauge pressure of a column of water at the base of the piezometer, and the elevation head is the relative potential energy in terms of an elevation. The head equation, a simplified form of the Bernoulli principle for ...
Pressure head is a component of hydraulic head, in which it is combined with elevation head. When considering dynamic (flowing) systems, there is a third term needed: velocity head. Thus, the three terms of velocity head, elevation head, and pressure head appear in the head equation derived from the Bernoulli equation for incompressible fluids:
If an NPSH A is say 10 bar then the pump you are using will deliver exactly 10 bar more over the entire operational curve of a pump than its listed operational curve. Example: A pump with a max. pressure head of 8 bar (80 metres) will actually run at 18 bar if the NPSH A is 10 bar. i.e.: 8 bar (pump curve) plus 10 bar NPSH A = 18 bar.