Any analyte that can be oxidized or reduced is a candidate for amperometric detection. The simplest form of amperometric detection is single-potential, or direct current (DC), amperometry. A voltage (potential) is applied between two electrodes positioned in the column effluent. The measured current changes as an electroactive analyte is ...
The charged aerosol detector (CAD) is a detector used in conjunction with high-performance liquid chromatography (HPLC) and ultra high-performance liquid chromatography (UHPLC) to measure the amount of chemicals in a sample by creating charged aerosol particles which are detected using an electrometer.
The amperometric method is used by some meters and measures the electric current generated at a specific point in time by the glucose reaction. This is analogous to throwing a ball and using the speed at which it is travelling at a point in time to estimate how hard it was thrown.
Double-pulsed chronoamperometry waveform showing integrated region for charge determination.. In electrochemistry, chronoamperometry is an analytical technique in which the electric potential of the working electrode is stepped and the resulting current from faradaic processes occurring at the electrode (caused by the potential step) is monitored as a function of time.
A pulse-height analyzer (PHA) is an instrument that accepts electronic pulses of varying heights from particle and event detectors, digitizes the pulse heights, and saves the number of pulses of each height in registers or channels, thus recording a pulse-height spectrum or pulse-height distribution used for later pulse-height analysis.
In the electron capture mode, the PDD is a selective detector for monitoring high electron affinity compounds such as freons, chlorinated pesticides, and other halogen compounds. For this type of compound, the minimum detectable quantity (MDQ) is at the femtogram ( 10 − 15 g {\displaystyle 10^{-15}\,\mathrm {g} } ) or picogram ( 10 − 12 g ...
Differential pulse voltammetry: An electrochemical technique similar to normal pulse voltammetry but the applied base potential is increased or decreased steadily, and the pulse height: base height ratio is kept constant. In DPV, measurements of current are taken twice during each drop, first immediately before the pulse and second before the ...
A microwave power meter is an instrument which measures the electrical power at microwave frequencies typically in the range 100 MHz to 40 GHz.. Usually a microwave power meter will consist of a measuring head which contains the actual power sensing element, connected via a cable to the meter proper, which displays the power reading.