The preloads for the unlubricated bolt sample had a standard deviation from the mean value of 1100 lbf, whereas the lubricated sample had a standard deviation of 680 lbf. If the preload value and torques are used in the above relation to solve for the nut factor it is found to be K = 0.208, which is very close to the recommended value of 0.20 [ 8 ]
However, slippage of a slip-critical connection in columns may lead to column instability. Slippage of a slip critical joint in a roof truss could result in unintended ponding effects. The faying surfaces of slip-critical connections must be properly prepared in order to maximize friction forces between the surfaces joined.
An ICD is the umbrella document over the system interfaces; examples of what these interface specifications should describe include: The inputs and outputs of a single system, documented in individual SIRS (Software Interface Requirements Specifications) and HIRS (Hardware Interface Requirements Specifications) documents, would fall under "The Wikipedia Interface Control Document".
Those phone calls and the bolt substitutions convinced him to recalculate the wind loads, including the diagonal wind loads. On July 24, 1978, LeMessurier went to his office and conducted calculations on Citicorp Center's design. [21] [22] He had thought that perpendicular winds were the critical case for the building rather than quartering winds.
BBN chose to make the IMP hardware calculate the checksum, because it was a faster option than using a software calculation. The IMP was initially conceived as being connected to one host computer per site, but at the insistence of researchers and students from the host sites, each IMP was ultimately designed to connect to multiple host computers.
Get AOL Mail for FREE! Manage your email like never before with travel, photo & document views. Personalize your inbox with themes & tabs. You've Got Mail!
Shear and Bending moment diagram for a simply supported beam with a concentrated load at mid-span. Shear force and bending moment diagrams are analytical tools used in conjunction with structural analysis to help perform structural design by determining the value of shear forces and bending moments at a given point of a structural element such as a beam.
The truss is rested on the notches and bolted into place. A special plate/bracket may be added to increase connection load transfer capabilities. With mechanically-laminated posts, the truss may rest on a shortened outer-ply or on a shortened inner-ply. The later scenario places the bolts in double shear and is a very effective connection.