Impedance cardiography (ICG) is a non-invasive technology measuring total electrical conductivity of the thorax and its changes in time to process continuously a number of cardiodynamic parameters, such as stroke volume (SV), heart rate (HR), cardiac output (CO), ventricular ejection time (VET), pre-ejection period and used to detect the impedance changes caused by a high-frequency, low ...
A normal chest X-ray after placement of an ICD, showing the ICD generator in the upper left chest and the ICD lead in the right ventricle of the heart. Note the 2 opaque coils along the ICD lead. The process of implantation of an ICD system is similar to implantation of an artificial pacemaker. In fact, ICDs are composed of an ICD generator and ...
Defibrillation is a treatment for life-threatening cardiac arrhythmias, specifically ventricular fibrillation (V-Fib) and non-perfusing ventricular tachycardia (V-Tach). [1] [2] A defibrillator delivers a dose of electric current (often called a counter-shock) to the heart.
Pad placement for electrical cardioversion a cardiac arrhythmia may be either anterior-posterior or anterior-lateral. In an anterior-posterior setup one pad is placed on the chest and the other pad is placed on the back. In an anterior-lateral setup, one pad is placed on the chest and the other pad is placed along the left midaxillary line.
CPR involves chest compressions for adults between 5 cm (2.0 in) and 6 cm (2.4 in) deep and at a rate of at least 100 to 120 per minute. [2] The rescuer may also provide artificial ventilation by either exhaling air into the subject's mouth or nose ( mouth-to-mouth resuscitation ) or using a device that pushes air into the subject's lungs ...
Depending on the physique of a person, the S-ICD may be more visible with bare chest. The procedure usually requires deep sedation or general anaesthesia, as creating a larger pocket between the muscles and tunnelling the lead over the sternum, as well as performing defibrillation threshold testing, can be quite painful.
During transcutaneous pacing, pads are placed on the patient's chest, either in the anterior/lateral position or the anterior/posterior position. The anterior/posterior position is preferred as it minimizes transthoracic electrical impedance by "sandwiching" the heart between the two pads [ citation needed ] .
A wearable cardioverter defibrillator (WCD) is a non-invasive, external device for patients at risk of sudden cardiac arrest (SCA). [1] It allows physicians time to assess their patient's arrhythmic risk and see if their ejection fraction improves before determining the next steps in patient care.