Ad
related to: dc load line analysis
Search results
Results From The WOW.Com Content Network
Once a DC operating point is defined by the DC load line, an AC load line can be drawn through the Q point. The AC load line is a straight line with a slope equal to the AC impedance facing the nonlinear device, which is in general different from the DC resistance. The ratio of AC voltage to current in the device is defined by this line.
In power engineering, the power-flow study, or load-flow study, is a numerical analysis of the flow of electric power in an interconnected system. A power-flow study usually uses simplified notations such as a one-line diagram and per-unit system, and focuses on various aspects of AC power parameters, such as Voltage, voltage angles, real power and reactive power.
The method is as follows: from linear network analysis the output transfer function (that is output voltage against output current) is calculated for the network of resistor(s) and the generator driving them. This will be a straight line (called the load line) and can readily be superimposed on the transfer function plot of the non-linear ...
A load line diagram, illustrating an operating point in the transistor's active region.. Biasing is the setting of the DC operating point of an electronic component. For bipolar junction transistors (BJTs), the operating point is defined as the steady-state DC collector-emitter voltage and the collector current with no input signal applied.
For a very long transmission line, these lower losses (and reduced construction cost of a DC line) can offset the additional cost of the required converter stations at each end.In DC transmission line, the mercury arc rectifier converts the alternating current into the DC. [3] The DC transmission line transmits the bulk power over long distance.
A 345 kV line carrying the same load across the same distance has losses of 4.2%. [25] For a given amount of power, a higher voltage reduces the current and thus the resistive losses . For example, raising the voltage by a factor of 10 reduces the current by a corresponding factor of 10 and therefore the I 2 R {\displaystyle I^{2}R} losses by a ...
Discover the latest breaking news in the U.S. and around the world — politics, weather, entertainment, lifestyle, finance, sports and much more.
The DC solution of an electric circuit is the solution where all voltages and currents are constant. Any stationary voltage or current waveform can be decomposed into a sum of a DC component and a zero-mean time-varying component; the DC component is defined to be the expected value, or the average value of the voltage or current over all time.