When.com Web Search

  1. Ads

    related to: microscope iris diaphragm vs condenser

Search results

  1. Results From The WOW.Com Content Network
  2. Condenser (optics) - Wikipedia

    en.wikipedia.org/wiki/Condenser_(optics)

    The Arlow-Abbe condenser is a modified Abbe condenser that replaces the iris diaphragm, filter holder, lamp and lamp optics with a small OLED or LCD digital display unit. The display unit allows for digitally synthesised filters for dark-field, Rheinberg, oblique and dynamic (constantly changing) illumination under direct computer control.

  3. Köhler illumination - Wikipedia

    en.wikipedia.org/wiki/Köhler_illumination

    Furthermore, altering the size of the condenser diaphragm allows adjustment of sample depth of field by altering the effective numerical aperture of the microscope. The role of the condenser diaphragm is analogous to the aperture in photography although the condenser diaphragm of a microscope functions by controlling illumination of the ...

  4. Bright-field microscopy - Wikipedia

    en.wikipedia.org/wiki/Bright-field_microscopy

    A bright-field microscope has many important parts including; the condenser, the objective lens, the ocular lens, the diaphragm, and the aperture. Some other pieces of the microscope that are commonly known are the arm, the head, the illuminator, the base, the stage, the adjusters, and the brightness adjuster.

  5. Diaphragm (optics) - Wikipedia

    en.wikipedia.org/wiki/Diaphragm_(optics)

    Nine-blade iris Pentacon 2.8/135 lens with 15-blade iris Aperture mechanism of Canon 50mm f/1.8 II lens, with five blades In the human eye, the iris (light brown) acts as the diaphragm and continuously constricts and dilates its aperture (the pupil) A 750nm titanium-sapphire laser beam passing through an iris diaphragm, while opening and closing the iris.

  6. Differential interference contrast microscopy - Wikipedia

    en.wikipedia.org/wiki/Differential_interference...

    The Nomarski prism causes the two rays to come to a focal point outside the body of the prism, and so allows greater flexibility when setting up the microscope, as the prism can be actively focused. 3. The two rays are focused by the condenser for passage through the sample. These two rays are focused so they will pass through two adjacent ...

  7. Dark-field microscopy - Wikipedia

    en.wikipedia.org/wiki/Dark-field_microscopy

    Light enters the microscope for illumination of the sample. A specially sized disc, the patch stop (see figure), blocks some light from the light source, leaving an outer ring of illumination. A wide phase annulus can also be reasonably substituted at low magnification. The condenser lens focuses the light towards the sample. The light enters ...

  8. Conoscopic interference pattern - Wikipedia

    en.wikipedia.org/wiki/Conoscopic_interference...

    The microscope's condenser is brought up close underneath the specimen to produce a wide divergence of polarised rays through a small point, and light intensity increased as much as possible (e.g., turning up the bulb and opening the diaphragm). A high power objective lens is typically used.

  9. Optical microscope - Wikipedia

    en.wikipedia.org/wiki/Optical_microscope

    The optical microscope, also referred to as a light microscope, is a type of microscope that commonly uses visible light and a system of lenses to generate magnified images of small objects. Optical microscopes are the oldest design of microscope and were possibly invented in their present compound form in the 17th century.