  2. Inrush current - Wikipedia

    en.wikipedia.org/wiki/Inrush_current

    For example, wall switches intended to control incandescent lamps will have a "T" rating, indicating that they can safely control circuits with the large inrush currents of incandescent lamps. The inrush may be as much as 14 times the steady-state current and may persist for a few milliseconds for smaller lamps up to several seconds for lamps ...

  3. Utilization categories - Wikipedia

    en.wikipedia.org/wiki/Utilization_categories

    Switching of mixed resistive and inductive loads, including moderate overloads: 60947-3 AC-23: Switching of motor loads or other highly inductive loads: 60947-3 AC-31A AC-31B ³) Non-inductive or weakly inductive loads 60947-6-1 AC-33A AC33B³) Motor loads or mixed loads including motors, resistors and up to 30% incandescent lamp load 60947-6-1 ...

  4. Load bank - Wikipedia

    en.wikipedia.org/wiki/Load_bank

    An inductive load consists of an iron-core reactive element which, when used in conjunction with a resistive load bank, creates a lagging power factor load. Typically, the inductive load will be rated at a numeric value 75% that of the corresponding resistive load such that when applied together a resultant 0.8 power factor load is provided.

  5. Impedance matching - Wikipedia

    en.wikipedia.org/wiki/Impedance_matching

    For example, in order to match an inductive load into a real impedance, a capacitor needs to be used. If the load impedance becomes capacitive, the matching element must be replaced by an inductor. In many cases, there is a need to use the same circuit to match a broad range of load impedance and thus simplify the circuit design.

  6. Induction generator - Wikipedia

    en.wikipedia.org/wiki/Induction_generator

    As an example, consider the use of a 10 hp, 1760 r/min, 440 V, three-phase induction motor (a.k.a. induction electrical machine in an asynchronous generator regime) as asynchronous generator. The full-load current of the motor is 10 A and the full-load power factor is 0.8. Required capacitance per phase if capacitors are connected in delta:

  7. Magne Charge - Wikipedia

    en.wikipedia.org/wiki/Magne_Charge

    The inductive coupling system was designed to be safe when used in the rain, and was demonstrated in operation fully submerged in water. [ 4 ] In 2011 the California Energy Commission created the Reconnect California Program , a grant program to upgrade and expand existing publicly available EV charging infrastructure to the latest version of ...

  8. Inductive coupling - Wikipedia

    en.wikipedia.org/wiki/Inductive_coupling

    Low-frequency induction can be a dangerous form of inductive coupling when it happens inadvertently. For example, if a long-distance metal pipeline is installed along a right of way in parallel with a high-voltage power line, the power line can induce current on the pipe. Since the pipe is a conductor, insulated by its protective coating from ...

  9. Electrical load - Wikipedia

    en.wikipedia.org/wiki/Electrical_load

    If an electric circuit has an output port, a pair of terminals that produces an electrical signal, the circuit connected to this terminal (or its input impedance) is the load. For example, if a CD player is connected to an amplifier, the CD player is the source, and the amplifier is the load, [2] and to continue the concept, if loudspeakers are ...