Switching of mixed resistive and inductive loads, including moderate overloads: 60947-3 AC-23: Switching of motor loads or other highly inductive loads: 60947-3 AC-31A AC-31B ³) Non-inductive or weakly inductive loads 60947-6-1 AC-33A AC33B³) Motor loads or mixed loads including motors, resistors and up to 30% incandescent lamp load 60947-6-1 ...
For example, wall switches intended to control incandescent lamps will have a "T" rating, indicating that they can safely control circuits with the large inrush currents of incandescent lamps. The inrush may be as much as 14 times the steady-state current and may persist for a few milliseconds for smaller lamps up to several seconds for lamps ...
An inductive load consists of an iron-core reactive element which, when used in conjunction with a resistive load bank, creates a lagging power factor load. Typically, the inductive load will be rated at a numeric value 75% that of the corresponding resistive load such that when applied together a resultant 0.8 power factor load is provided.
For example, in order to match an inductive load into a real impedance, a capacitor needs to be used. If the load impedance becomes capacitive, the matching element must be replaced by an inductor. In many cases, there is a need to use the same circuit to match a broad range of load impedance and thus simplify the circuit design.
As an example, consider the use of a 10 hp, 1760 r/min, 440 V, three-phase induction motor (a.k.a. induction electrical machine in an asynchronous generator regime) as asynchronous generator. The full-load current of the motor is 10 A and the full-load power factor is 0.8. Required capacitance per phase if capacitors are connected in delta:
Low-frequency induction can be a dangerous form of inductive coupling when it happens inadvertently. For example, if a long-distance metal pipeline is installed along a right of way in parallel with a high-voltage power line, the power line can induce current on the pipe. Since the pipe is a conductor, insulated by its protective coating from ...
Inductive reactance is the opposition of an inductor to an alternating current. [21] It is defined analogously to electrical resistance in a resistor, as the ratio of the amplitude (peak value) of the alternating voltage to current in the component = = Reactance has units of ohms.
Reducing energy loads of main systems equipment providing heating, cooling and water heating can be achieved by upgrading physical equipment including replacing older equipment with newer, more energy-efficient units, upgrading the building envelope with insulation and higher-grade windows, creating more efficient zoning within heating/cooling air distribution ducts, and deployment of advanced ...