The fire requirements on riser cable are not as strict. Thus, plenum cable can always replace riser cable, but riser cable cannot replace plenum cable in plenum spaces. Both plenum and riser cables commonly include a rope or polymer filament with high tensile strength, which helps support the weight of the cable when it is dangling in an open ...
Mineral-insulated copper-clad cable is a variety of electrical cable made from copper conductors inside a copper sheath, insulated by inorganic magnesium oxide powder. The name is often abbreviated to MICC or MI cable, and colloquially known as pyro (because the original manufacturer and vendor for this product in the UK was a company called ...
While twisted pair cable for networking and telephone service is the most common form of plenum cable, coaxial cable also needs to be plenum-rated for safety. High-voltage electrical equipment (generally regarded as being over 50 V) is not permitted to be exposed in the plenum space above a drop ceiling but must be enclosed in conduit or ...
Charger for a plus-minus net fence. An electric fence is a barrier that uses electric shocks to deter humans and other animals [note 1] from crossing a boundary. The voltage of the shocks may cause discomfort or death. Most electric fences are used for agricultural purposes and other non-human animal control.
It was created in 1957 through a merger of McGraw Electric and Thomas A. Edison, Inc., and was in turn acquired by Cooper Industries in 1985. Today, the McGraw-Edison brand is used on industrial, commercial, and institutional lighting products, and has been owned by the Pennsylvania Transformer Technologies Inc. since 1996.
The MC4 connector is UL rated at 1500 V DC and up to 95 A with the 6AWG PV Cable. MC4-Evo 2 has both UL and IEC certification ratings of 1500 V DC and up to 70 A with 10mm² PV Cable, depending on the conductor size used in pairs.
BS 6231 is a British Standard, last revised in 2006 by the BSI Group. [4] This standard specifies the performance and construction requirements of electrical cables that are single core, non-sheathed, PVC-insulated and rated 600/1000 V. Wire meeting the requirements of type CK of this standard is used as tri-rated wire.
A non-plenum airspace can become a plenum airspace by accident if the ductwork is disconnected and not properly repaired and resealed. Ductwork disconnection can occur due to building damage such as earthquakes, aging, or adverse environment causing the metal to corrode and fall apart, or simply negligence on the part of building contractors ...