When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Calibration curve - Wikipedia

    en.wikipedia.org/wiki/Calibration_curve

    A calibration curve plot showing limit of detection (LOD), limit of quantification (LOQ), dynamic range, and limit of linearity (LOL).. In analytical chemistry, a calibration curve, also known as a standard curve, is a general method for determining the concentration of a substance in an unknown sample by comparing the unknown to a set of standard samples of known concentration. [1]

  3. Bjerrum plot - Wikipedia

    en.wikipedia.org/wiki/Bjerrum_plot

    Example Bjerrum plot: Change in carbonate system of seawater from ocean acidification.. A Bjerrum plot (named after Niels Bjerrum), sometimes also known as a Sillén diagram (after Lars Gunnar Sillén), or a Hägg diagram (after Gunnar Hägg) [1] is a graph of the concentrations of the different species of a polyprotic acid in a solution, as a function of pH, [2] when the solution is at ...

  4. Internal standard - Wikipedia

    en.wikipedia.org/wiki/Internal_standard

    In NMR spectroscopy, e.g. of the nuclei 1 H, 13 C and 29 Si, frequencies depend on the magnetic field, which is not the same across all experiments. Therefore, frequencies are reported as relative differences to tetramethylsilane (TMS), an internal standard that George Tiers proposed in 1958 and that the International Union of Pure and Applied Chemistry has since endorsed.

  5. Standard addition - Wikipedia

    en.wikipedia.org/wiki/Standard_addition

    Using the calibration curve method, the analyst can calibrate the spectrometer with a pure silver aqueous solutions, and use the calibration graph to determine the amount of silver present in the waste samples. This method, however, assumes the pure aqueous solution of silver and a photographic waste sample have the same matrix and therefore ...

  6. Chromatography - Wikipedia

    en.wikipedia.org/wiki/Chromatography

    Analytical chromatography – the use of chromatography to determine the existence and possibly also the concentration of analyte(s) in a sample. Bonded phase – a stationary phase that is covalently bonded to the support particles or to the inside wall of the column tubing. Chromatogram – the visual output of the chromatograph. In the case ...

  7. Distribution constant - Wikipedia

    en.wikipedia.org/wiki/Distribution_constant

    The distribution constant (or partition ratio) (K D) is the equilibrium constant for the distribution of an analyte in two immiscible solvents. [1] [2] [3]In chromatography, for a particular solvent, it is equal to the ratio of its molar concentration in the stationary phase to its molar concentration in the mobile phase, also approximating the ratio of the solubility of the solvent in each phase.

  8. Gas chromatography - Wikipedia

    en.wikipedia.org/wiki/Gas_chromatography

    Gas chromatography (GC) is a common type of chromatography used in analytical chemistry for separating and analyzing compounds that can be vaporized without decomposition. Typical uses of GC include testing the purity of a particular substance, or separating the different components of a mixture. [ 1 ]

  9. Column chromatography - Wikipedia

    en.wikipedia.org/wiki/Column_chromatography

    A simplified method of calculating chromatogram resolution is to use the plate model. [8] The plate model assumes that the column can be divided into a certain number of sections, or plates and the mass balance can be calculated for each individual plate. This approach approximates a typical chromatogram curve as a Gaussian distribution curve ...