  2. Airlift pump - Wikipedia

    en.wikipedia.org/wiki/Airlift_pump

    (The compressor is on the surface and no mechanical parts are needed in the well). However airlift wells must be much deeper than the water table to allow for submergence. Air is generally pumped at least as deep under the water as the water is to be lifted. (If the water table is 50 ft below, the air should be pumped 100 feet deep).

  3. Artificial lift - Wikipedia

    en.wikipedia.org/wiki/Artificial_lift

    Artificial lift is the use of artificial means to increase the flow of liquids, such as crude oil or water, from a production well. Generally this is achieved by the use of a mechanical device inside the well (known as pump or velocity string) or by decreasing the weight of the hydrostatic column by injecting gas into the liquid some distance down the well.

  4. Pumping station - Wikipedia

    en.wikipedia.org/wiki/Pumping_station

    Redundancy is built into the system so that in the event that any one pump is out of service, the remaining pump or pumps will handle the designed flow. The storage volume of the wet well between the "pump on" and "pump off" settings is designed to minimize pump starts and stops, but is not so long a retention time as to allow the sewage in the ...

  5. Completion (oil and gas wells) - Wikipedia

    en.wikipedia.org/wiki/Completion_(oil_and_gas_wells)

    Gas lift well: gas is fed into valves installed in mandrels in the tubing strip. The hydrostatic head is lowered and the fluid is gas lifted to the surface. Single-well alternate completions: in this instance there is a well with two zones. In order to produce from both the zones are isolated with packers.

  6. Backwashing (water treatment) - Wikipedia

    en.wikipedia.org/wiki/Backwashing_(water_treatment)

    Water to be filtered is then applied to the filter surface until the filter clogs and the backwash cycle needs to be repeated. [3]: 264–8 [4]: 10.53–10.58 [5]: 937–9 [6]: 8.11–8.18 [7]: 353–6 Some water treatment filters use surface wash systems that break up the heavily clogged, granular media surface layer.

  7. Pump - Wikipedia

    en.wikipedia.org/wiki/Pump

    A minimum flow protection system ensures that the pump is not operated below the minimum flow rate. The system protects the pump even if it is shut-in or dead-headed, that is, if the discharge line is completely closed. [44] The simplest minimum flow system is a pipe running from the pump discharge line back to the suction line.