When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Bus duct - Wikipedia

    en.wikipedia.org/wiki/Bus_duct

    5000 ampere copper and 4000 A aluminium bus ducts. In electric power distribution, a bus duct (also called busway) typically uses sheet metal, welded metal [1] or cast resin to contain and isolate copper or aluminium busbars for the purpose of conducting a substantial current of electricity.

  3. Busbar - Wikipedia

    en.wikipedia.org/wiki/Busbar

    The busbar's material composition and cross-sectional size determine the maximum current it can safely carry. Busbars can have a cross-sectional area of as little as 10 square millimetres (0.016 sq in), but electrical substations may use metal tubes 50 millimetres (2.0 in) in diameter or more as busbars.

  4. Electrical busbar system - Wikipedia

    en.wikipedia.org/wiki/Electrical_busbar_system

    Enclosure comparison with normal wiring & with busbar system. Electrical busbar systems [1] (sometimes simply referred to as busbar systems) are a modular approach to electrical wiring, where instead of a standard cable wiring to every single electrical device, the electrical devices are mounted onto an adapter which is directly fitted to a current carrying busbar.

  5. Isolated-phase bus - Wikipedia

    en.wikipedia.org/wiki/Isolated-phase_bus

    The consequences of a two- or three-phase fault between the generator and the first circuit breaker are therefore much more serious and often result in severe damage to the busbars and nearby equipment. Isolated-phase bus is made in ratings from 3000 amperes to 45,000 amperes, and rated for voltages from 5000 volts up to about 35,000 volts.

  6. List of IEC standards - Wikipedia

    en.wikipedia.org/wiki/List_of_IEC_standards

    IEC 60055 Paper-insulated metal-sheathed cables for rated voltages up to 18/30 kV (with copper or aluminium conductors and excluding gas-pressure and oil-filled cables) IEC 60059 IEC standard current ratings; IEC 60060 High-voltage test techniques; IEC 60061 Lamp caps and holders together with gauges for the control of interchangeability and safety

  7. Ampacity - Wikipedia

    en.wikipedia.org/wiki/Ampacity

    A lower rating will apply if multiple conductors are in proximity, since each contributes heat to the others and diminishes the amount of external cooling of the conductors. Depending on the type of insulating material, common maximum allowable temperatures at the surface of the conductor are 60, 75, and 90 °C, often with an ambient air ...

  8. Bus coupler - Wikipedia

    en.wikipedia.org/wiki/Bus_coupler

    A bus coupler is a device which is used to couple one bus to the other without any interruption in power supply and without creating hazardous arcs. A bus coupler is a breaker used to couple two busbars to perform maintenance on other circuit breakers associated with that busbar.

  9. IEC 60228 - Wikipedia

    en.wikipedia.org/wiki/IEC_60228

    Comparison of SWG (red), AWG (blue) and IEC 60228 (black) wire gauge sizes from 0.03 to 200 mm² to scale on a 1 mm grid – in the SVG file, hover over a size to highlight it. In engineering applications, it is often most convenient to describe a wire in terms of its cross-section area, rather than its diameter, because the cross section is directly proportional to its strength and weight ...