Search results
Results From The WOW.Com Content Network
Setting a capacitor value to zero corresponds to an open circuit, while a zero-valued inductor is a short circuit. So for calculation of the , all other capacitors are open-circuited and all other inductors are short-circuited. This is the essence of the ZVT method, which reduces to OCT when only capacitors are involved.
Then the resistance seen by the test voltage is found using the circuit in the right panel of Figure 1 and is simply V X / I X = R 1. Form the product C 1 R 1. Add these terms. In effect, it is as though each capacitor charges and discharges through the resistance found in the circuit when the other capacitor is an open circuit.
In many vacuum tube circuits, interstage coupling capacitors are used to conduct a varying signal from the plate of one tube to the grid circuit of the next stage. A leaky capacitor can cause the grid circuit voltage to be raised from its normal bias setting, causing excessive current or signal distortion in the downstream tube.
The transfer constants are calculated under similar zero- and infinite-value conditions of reactive elements used in the Cochran-Grabel (CG) method [2] to calculate time constants, but calculating the low-frequency transfer functions from a defined input source to the output terminal, instead of the resistance seen by the reactive elements.
The signal delay of a wire or other circuit, measured as group delay or phase delay or the effective propagation delay of a digital transition, may be dominated by resistive-capacitive effects, depending on the distance and other parameters, or may alternatively be dominated by inductive, wave, and speed of light effects in other realms.
Figure 1: Essential meshes of the planar circuit labeled 1, 2, and 3. R 1, R 2, R 3, 1/sC, and sL represent the impedance of the resistors, capacitor, and inductor values in the s-domain. V s and I s are the values of the voltage source and current source, respectively. Mesh analysis (or the mesh current method) is a circuit analysis method for ...
The points where the characteristic curve and the load line intersect are the possible operating point(s) of the circuit; at these points the current and voltage parameters of both parts of the circuit match. [1] The example at right shows how a load line is used to determine the current and voltage in a simple diode circuit.
Differential Equations: Applied to model and analyze the behavior of circuits over time. Used in the study of filters, oscillators, and transient responses of circuits. Complex Numbers and Complex Analysis: Important for circuit analysis and impedance calculations. Used in signal processing and to solve problems involving sinusoidal signals.