Concrete cover, in reinforced concrete, is the least distance between the surface of embedded reinforcement and the outer surface of the concrete (ACI 130). The concrete cover depth can be measured with a cover meter. The purpose of concrete cover is to protect the reinforcement from corrosion, fire, and other potential damage.
The ACI Building Code Requirements put the following restrictions on amount of spiral reinforcement. ACI Code 7.10.4.2: For cast-in-place construction, size of spirals shall not be less than 3/8 in. diameter. ACI Code 7.10.4.3: Clear spacing between spirals shall not exceed 3 in., nor be less than 1in.
A concrete spacer with a plastic clip in use Concrete spacers in a precast element Diaphragm wall block on rebar for a Diaphragm wall. A rebar spacer is a short, rod-like device used to secure reinforcing steel bars, or rebar, within cast assemblies for reinforced concrete structures. The rebar spacers are fixed before the concrete is poured ...
The minimum concrete cover is normally regulated by design or building codes. If the reinforcement is too close to the surface, early failure due to corrosion may occur. The concrete cover depth can be measured with a cover meter. However, carbonated concrete incurs a durability problem only when there is also sufficient moisture and oxygen to ...
BS 1881:204 Testing concrete. Recommendations on the use of electromagnetic covermeters; DGZfP:B2: Guideline “für Bewehrungsnachweis und Überdeckungsmessung bei Stahl- und Spannbeton” DIN 1045: Guideline Concrete, reinforced and prestressed concrete structures; ACI Concrete Practices Non Destructive testing 228.2R-2.51: Covermeters
Conventionally the term concrete refers only to concrete that is reinforced with iron or steel. However, other materials are often used to reinforce concrete e.g. organic and inorganic fibres, composites in different forms. While compared to its compressive strength, concrete is weak in tension. Thus adding reinforcement increases the strength ...
Logo of Eurocode 2 An example of a concrete structure. In the Eurocode series of European standards (EN) related to construction, Eurocode 2: Design of concrete structures (abbreviated EN 1992 or, informally, EC 2) specifies technical rules for the design of concrete, reinforced concrete and prestressed concrete structures, using the limit state design philosophy.
The initiation time is related to the rate at which carbonation propagates in the concrete cover thickness.Once that carbonation reaches the steel surface, altering the local pH value of the environment, the protective thin film of oxides on the steel surface becomes instable, and corrosion initiates involving an extended portion of the steel surface.