When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Single-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Single-phase_electric_power

    Because the voltage of a single phase system reaches a peak value twice in each cycle, the instantaneous power is not constant. Standard frequencies of single-phase power systems are either 50 or 60 Hz. Special single-phase traction power networks may operate at 16.67 Hz or other frequencies to power electric railways. [1]

  3. Hydro-Québec's electricity transmission system - Wikipedia

    en.wikipedia.org/wiki/Hydro-Québec's_electricity...

    The 735 kV power line is said to lessen the environmental impact of power lines, as one single power line operating at this voltage carries the same amount of electric power as four 315 kV power lines, which would require a right-of-way wider than the 80.0–91.5 metres (262.5–300.2 ft) [29] [30] width required for a single 735 kV line.

  4. Quebec – New England Transmission - Wikipedia

    en.wikipedia.org/wiki/Quebec_–_New_England...

    450kV HVDC line (at right), on south side of Autoroute 20 east of the Nicolet station near Sainte-Eulalie, Quebec.. The Quebec – New England Transmission (officially known in Quebec as the Réseau multiterminal à courant continu (RMCC) [1] and also known as Phase I / Phase II [2] and the Radisson - Nicolet - Des Cantons circuit, [3] and known in New England as the Northern Pass) is a long ...

  5. Electric power distribution - Wikipedia

    en.wikipedia.org/wiki/Electric_power_distribution

    This gives a phase-to-phase voltage of 400 volts wye service and a single-phase voltage of 230 volts between any one phase and neutral. In the UK a typical urban or suburban low-voltage substation would normally be rated between 150 kVA and 1 MVA and supply a whole neighbourhood of a few hundred houses.

  6. Single-wire earth return - Wikipedia

    en.wikipedia.org/wiki/Single-wire_earth_return

    The voltage changes due to the transition from line-to-line to line-to-earth, typically reducing a 22 kV grid to 12.7 kV SWER or a 33 kV grid to 19.1 kV SWER. The SWER line is a single conductor that may stretch for tens or even hundreds of kilometres, with a number of distribution transformers along its length.

  7. Electric power transmission - Wikipedia

    en.wikipedia.org/wiki/Electric_power_transmission

    As of 2022, more than 10,000 power plant and energy storage projects were awaiting permission to connect to the US grid — 95% were zero-carbon resources. New power lines can take 10 years to plan, permit, and build. [33] Traditional power lines use a steel core surrounded by aluminum strands (Aluminium-conductor steel-reinforced cable).

  8. Split-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Split-phase_electric_power

    However, 130/225 V, three-wire, two-phase electric power discontinued systems called B1 are used to run old installations in small groups of houses when only two of the three-phase high-voltage conductors are used. The phase shift in Europe is 120°, as is the case with three-phase current. That's why we calculate 130V * √3 = 225V.

  9. Overhead power line - Wikipedia

    en.wikipedia.org/wiki/Overhead_power_line

    In 1985 overhead power line was built in Soviet Union between Kokshetau and the power station at Ekibastuz, this was a three-phase alternating current line at 1150 kV. In 1999, in Japan the first powerline designed for 1000 kV with 2 circuits were built, the Kita-Iwaki Powerline .