When.com Web Search

  1. Ad

    related to: reduced pressure vs double check

Search results

  1. Results From The WOW.Com Content Network
  2. Reduced pressure zone device - Wikipedia

    en.wikipedia.org/wiki/Reduced_pressure_zone_device

    A reduced pressure zone device (RPZD, RPZ, or RPZ valve) is a type of backflow prevention device used to protect water supplies from contamination. RPZDs may also be known as reduced pressure principle (RP), reduced pressure principle backflow prevention devices, [1] [2] reduced pressure zone assemblies (RPZA), [3] or reduced pressure principle ...

  3. Double check valve - Wikipedia

    en.wikipedia.org/wiki/Double_check_valve

    A double check valve or double check assembly (DCA) is a backflow prevention device designed to protect water supplies from contamination. [1] It is different from the two-way check valves (sometimes erroneously referred to as double check valves) used in air brake systems on heavy trucks which select from the highest pressure source. It ...

  4. Backflow prevention device - Wikipedia

    en.wikipedia.org/wiki/Backflow_prevention_device

    A check valve is a basic form of backflow prevention, but often more complex devices are required because check valves are not considered to be reliable, when compared to more sophisticated devices with redundancies and reduced-pressure zones. [further explanation needed]

  5. Backflow - Wikipedia

    en.wikipedia.org/wiki/Backflow

    A recent introduction to the UK has been the Reduced Pressure Zone (RPZ) valve, a form of double check valve where the intervening zone is drained and normally kept empty. [1] If the downstream valve leaks and permits backflow, this will drain out through the vent rather than building up pressure against the upstream valve.

  6. Chemigation valve - Wikipedia

    en.wikipedia.org/wiki/Chemigation_valve

    "Backflow prevention should include a check valve between the irrigation pump and the injection device to prevent backward flow; a low-pressure drain to prevent seepage past the check valve; a vacuum relief valve to ensure that a siphon cannot develop; and a check valve on the injection line."

  7. Atmospheric vacuum breaker - Wikipedia

    en.wikipedia.org/wiki/Atmospheric_vacuum_breaker

    Inside this elbow is a poppet valve that is held "up" by the water pressure found in the system, closing the air entrance to the device. If the pressure in the "upstream side" is reduced to atmospheric pressure or below, the poppet valve drops and allows air to enter the system, breaking the siphon. [1]

  8. During blood pressure check, there's a right way and wrong ...

    www.aol.com/news/during-blood-pressure-check...

    For example, if a person’s actual blood pressure is 134, and blood pressure is measured on a dangling arm, the reading could end up over 140, which is considered to be stage 2 hypertension.

  9. Pressure vacuum breaker - Wikipedia

    en.wikipedia.org/wiki/Pressure_vacuum_breaker

    A pressure vacuum breaker (PVB) is a type of backflow prevention device, used to keep non-potable (or contaminated) water from entering the water supply. A PVB is similar to an atmospheric vacuum breaker (AVB), except that the PVB contains a spring-loaded poppet. This makes it acceptable for applications that are high hazard or where valves are ...