When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Droop speed control - Wikipedia

    en.wikipedia.org/wiki/Droop_speed_control

    Droop speed control is a control mode used for AC electrical power generators, whereby the power output of a generator reduces as the line frequency increases. It is commonly used as the speed control mode of the governor of a prime mover driving a synchronous generator connected to an electrical grid. It works by controlling the rate of power ...

  3. Voltage droop - Wikipedia

    en.wikipedia.org/wiki/Voltage_droop

    Voltage droop is the intentional loss in output voltage from a device as it drives a load. Adding droop in a voltage regulation circuit increases the headroom for load transients . All electrical systems have some amount of resistance between the regulator output and the load.

  4. Static synchronous compensator - Wikipedia

    en.wikipedia.org/wiki/Static_synchronous_compensator

    The rate at which it does this is set by the slope, which functions similar to a generator's droop speed control. This slope is programmable and can be set to a high value (to have the STATCOM regulate voltage like a traditional fixed reactive device) or to near zero, producing a very flat line and reserving the STATCOMs capacity for dynamic or ...

  5. Induction generator - Wikipedia

    en.wikipedia.org/wiki/Induction_generator

    An induction generator or asynchronous generator is a type of alternating current (AC) electrical generator that uses the principles of induction motors to produce electric power. Induction generators operate by mechanically turning their rotors faster than synchronous speed.

  6. Flexible AC transmission system - Wikipedia

    en.wikipedia.org/wiki/Flexible_AC_transmission...

    From the above equations, it can be seen that there are three variables that affect real and reactive power flow on a Transmission Line: [12] the voltage magnitudes at either bus, the line reactance between the buses, and the voltage phase-angle difference between the buses. All FACTs devices operation on the fundamental principal that changing ...

  7. Short circuit ratio (electrical grid) - Wikipedia

    en.wikipedia.org/wiki/Short_circuit_ratio...

    In an electrical grid, the short circuit ratio (or SCR) is the ratio of: the short circuit apparent power (SCMVA) in the case of a line-line-line-ground (3LG) fault at the location in the grid where some generator is connected, to: the power rating of the generator itself (GMW).

  8. Swing equation - Wikipedia

    en.wikipedia.org/wiki/Swing_equation

    The equation describing the relative motion is known as the swing equation, which is a non-linear second order differential equation that describes the swing of the rotor of synchronous machine. The power exchange between the mechanical rotor and the electrical grid due to the rotor swing (acceleration and deceleration) is called Inertial ...

  9. Proportional–integral–derivative controller - Wikipedia

    en.wikipedia.org/wiki/Proportional–integral...

    In the standard form of the equation (see later in article), and are respectively replaced by / and ; the advantage of this being that and have some understandable physical meaning, as they represent an integration time and a derivative time respectively.