Search results
Results From The WOW.Com Content Network
The Purkinje fibers are further specialized to rapidly conduct impulses (having numerous fast voltage-gated sodium channels and mitochondria, and fewer myofibrils, than the surrounding muscle tissue). Purkinje fibers take up stain differently from the surrounding muscle cells because of having relatively fewer myofibrils than other cardiac cells.
An impulse (action potential) that originates from the SA node at a relative rate of 60–100 bpm is known as a normal sinus rhythm. If SA nodal impulses occur at a rate less than 60 bpm, the heart rhythm is known as sinus bradycardia. If SA nodal impulses occur at a rate exceeding 100 bpm, the consequent rapid heart rate is sinus tachycardia ...
Cardiac physiology or heart function is the study of healthy, unimpaired function of the heart: involving blood flow; myocardium structure; the electrical conduction system of the heart; the cardiac cycle and cardiac output and how these interact and depend on one another.
The blood supply of the AV node is from the atrioventricular nodal branch. The origin of this artery is most commonly (80–90% of hearts) a branch of the right coronary artery, with the remainder originating from the left circumflex artery. [4] [5] [6] This is associated with the dominance of the coronary artery circulation.
The cardiac pacemaker is the heart's natural rhythm generator. It employs pacemaker cells that generate electrical impulses, known as cardiac action potentials.These potentials cause the cardiac muscle to contract, and the rate of which these muscles contract determines the heart rate.
These cells produce an electrical impulse known as a cardiac action potential that travels through the electrical conduction system of the heart, causing it to contract. In a healthy heart, the SA node continuously produces action potentials, setting the rhythm of the heart (sinus rhythm), and so is known as the heart's natural pacemaker.
An artificial cardiac pacemaker (or artificial pacemaker, so as not to be confused with the natural cardiac pacemaker) or just pacemaker is an implanted medical device that generates electrical impulses delivered by electrodes to the chambers of the heart either the upper atria, or lower ventricles to cause the targeted chambers to contract and ...
In non-pacemaker cells (i.e. ventricular cells), this is produced predominantly by the activation of Na + channels, which increases the membrane conductance (flow) of Na + (g Na). These channels are activated when an action potential arrives from a neighbouring cell, through gap junctions. When this happens, the voltage within the cell ...