When.com Web Search

  1. Ads

    related to: residential square foot per ton air conditioning unit not running cold water

Search results

  1. Results From The WOW.Com Content Network
  2. Deep water source cooling - Wikipedia

    en.wikipedia.org/wiki/Deep_water_source_cooling

    Deep water source cooling (DWSC) or deep water air cooling is a form of air cooling for process and comfort space cooling which uses a large body of naturally cold water as a heat sink. It uses water at 4 to 10 degrees Celsius drawn from deep areas within lakes, oceans, aquifers or rivers, which is pumped through the one side of a heat exchanger .

  3. Ton of refrigeration - Wikipedia

    en.wikipedia.org/wiki/Ton_of_refrigeration

    Just as horsepower and candlepower were intuitive units of measure for people living through the transition from horse to steam power [3] and from flame-based to electric lighting, so was the ton of refrigeration an intuitive unit of measure during a technological change, as the ice trade gradually included growing percentages of artificial ice ...

  4. Seasonal energy efficiency ratio - Wikipedia

    en.wikipedia.org/wiki/Seasonal_energy_efficiency...

    In the United States, the efficiency of air conditioners is often rated by the seasonal energy efficiency ratio (SEER) which is defined by the Air Conditioning, Heating, and Refrigeration Institute, a trade association, in its 2008 standard AHRI 210/240, Performance Rating of Unitary Air-Conditioning and Air-Source Heat Pump Equipment. [1]

  5. Coefficient of performance - Wikipedia

    en.wikipedia.org/wiki/Coefficient_of_performance

    Less work is required to move heat than for conversion into heat, and because of this, heat pumps, air conditioners and refrigeration systems can have a coefficient of performance greater than one. The COP is highly dependent on operating conditions, especially absolute temperature and relative temperature between sink and system, and is often ...

  6. Cooling capacity - Wikipedia

    en.wikipedia.org/wiki/Cooling_capacity

    The SI unit is watt (W). Another unit common in non-metric regions or sectors is the ton of refrigeration, which describes the amount of water at freezing temperature that can be frozen in 24 hours, equivalent to 3.5 kW or 12,000 BTU/h. [1] [2] [3]

  7. Water chiller - Wikipedia

    en.wikipedia.org/wiki/Water_chiller

    In air conditioning, chilled water is often used to cool a building's air and equipment, especially in situations where many individual rooms must be controlled separately, such as a hotel. A chiller lowers water temperature to between 40 °F (4 °C) and 45 °F (7 °C) before the water is pumped to the location to be cooled. [2]