The committee's initial report evolved into NFPA 13, Standard for the Installation of Sprinkler Systems, the most widely used fire sprinkler standard. [6] Around 1904, the NFPA began to expand its membership from affiliates of fire insurance companies to many other organizations and individuals, and also expanded its mission beyond promulgating ...
The primary fire code writing organization is the private National Fire Protection Association or NFPA. NFPA sets the standards for technical aspects of sprinklers installed in the USA. Building codes, which specify which buildings require sprinklers are generally left to local jurisdictions. However, there are some exceptions:
The 2002 edition of the NFPA #13 standard, section 3.6.1 defines quick response sprinklers as having a response time index (RTI) of 50 (meter-seconds) 1/2 or less. RTI is a measure of how thermally responsive the heat-responsive element of the sprinkler is, measured as the time needed to raise the temperature of the sprinkler bulb to 63% of the ...
Sprinkler fitting is a skilled trade that consists of assembling, installing, testing, repairing, inspecting, and certifying automatic fire suppression systems and their associated piping in commercial, industrial and residential buildings.
These standards are widely accepted as the standards of knowledge and skills measurement for all firefighters in North America and beyond. Essentials of Fire Fighting includes an appendix that lists the job performance requirements from the NFPA standards and cross-references those requirements to the chapters within the manual. These chapters ...
The main standard that governs fire pump fixed-place installations in North America is the National Fire Protection Association's NFPA 20 Standard for the Installation of Stationary Fire Pumps for Fire Protection. [1] Fire pumps are powered most commonly by an electric motor or a diesel engine, or, occasionally a steam turbine.
The hydraulic calculation procedure is defined in the applicable reference model codes such as that published by the US-based National Fire Protection Association (NFPA), [2] or the EN 12845 standard, Fixed firefighting system – Automatic sprinkler systems – Design, installation and maintenance. [3]
The Life Safety Code is coordinated with hundreds of other building codes and standards such as National Electrical Code NFPA 70, fuel-gas, mechanical, plumbing (for sprinklers and standpipes), energy and fire codes. Normally, the Life Safety Code is used by architects and designers of vehicles and vessels used for human occupancy.