When.com Web Search

  1. Ads

    related to: positive side vs negative waterproofing system for toilet repair

Search results

  1. Results From The WOW.Com Content Network
  2. Plumbing fixture - Wikipedia

    en.wikipedia.org/wiki/Plumbing_fixture

    The visible water surface in a toilet is the top of the trap's water seal. Each fixture drain, with exceptions, must be vented so that negative air pressure in the drain cannot siphon the trap dry, to prevent positive air pressure in the sewer from forcing gases past the water seal, and to prevent explosive sewer gas buildup.

  3. Drain-waste-vent system - Wikipedia

    en.wikipedia.org/wiki/Drain-waste-vent_system

    In the U.S., every plumbing fixture must also be coupled to the system's vent piping. [1] Without a vent, negative pressure can slow the flow of water leaving the system, resulting in clogs, or cause siphonage to empty a trap. The high point of the vent system (the top of its "soil stack") must be open to the exterior at atmospheric pressure.

  4. Waterproofing - Wikipedia

    en.wikipedia.org/wiki/Waterproofing

    Waterproofing with two component system. In buildings using earth sheltering, too much humidity can be a potential problem, so waterproofing is critical. Water seepage can lead to mold growth, causing significant damage and air quality issues. Properly waterproofing foundation walls is required to prevent deterioration and seepage.

  5. Basement waterproofing - Wikipedia

    en.wikipedia.org/wiki/Basement_waterproofing

    The drainage system collects any water entering the basement and drains it to an internally placed sump pump system, which will then pump the water out of the basement. The Federal Emergency Management Agency (FEMA) recommends basement waterproofing with a water alarm and "battery-operated backup pump" as a preventive measure against the high ...

  6. Trap (plumbing) - Wikipedia

    en.wikipedia.org/wiki/Trap_(plumbing)

    The U-bend could not jam, so, unlike the S-bend, it did not need an overflow. In the United States, traps are commonly referred to as P-traps. It is the addition of a 90 degree fitting on the outlet side of a U-bend, thereby creating a P-like shape (oriented horizontally). It is also referred to as a sink trap because it is installed under most ...

  7. Bituminous waterproofing - Wikipedia

    en.wikipedia.org/wiki/Bituminous_waterproofing

    Bituminous waterproofing systems are designed to protect residential and commercial buildings. Bitumen (asphalt or coal-tar pitch) is a material made up of organic liquids that are highly sticky, viscous , and waterproof. [ 1 ]

  8. Siphon - Wikipedia

    en.wikipedia.org/wiki/Siphon

    However, as the siphon is a single system, v B = v C and the intermediate high point does limit the maximum velocity. The drain point cannot be lowered indefinitely to increase the velocity. Equation 3 will limit the velocity to retain a positive pressure at the intermediate high point to prevent cavitation. The maximum velocity may be ...

  9. Cathodic protection - Wikipedia

    en.wikipedia.org/wiki/Cathodic_protection

    Galvanic systems are "constant potential" systems that aim to restore the concrete's natural protective environment by providing a high initial current to restore passivity. It then reverts to a lower sacrificial current, while harmful negative chloride ions migrate away from the steel and towards the positive anode.