When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Isolation condenser - Wikipedia

    en.wikipedia.org/wiki/Isolation_condenser

    Steam enters the IC condenser and condenses until it is filled with water. When the IC system is activated, a valve at the bottom of the IC condenser is opened which connects to a lower area on the reactor. The water falls to the reactor via gravity, allowing the condenser to fill with steam, which then condenses.

  3. Fukushima nuclear accident (Unit 1 Reactor) - Wikipedia

    en.wikipedia.org/wiki/Fukushima_nuclear_accident...

    To cool the reactor, operators resorted to the plant's Emergency core-cooling systems (ECCS), including the isolation condensers, and the High Pressure Coolant Injection systems (HPCI). According to NHK, the isolation condenser system had not been activated in the previous 40 years, and no one present had ever witnessed its operation. [19]

  4. Fukushima nuclear accident cleanup - Wikipedia

    en.wikipedia.org/wiki/Fukushima_nuclear_accident...

    The Fukushima disaster cleanup is an ongoing attempt to limit radioactive contamination from the three nuclear reactors involved in the Fukushima Daiichi nuclear disaster that followed the earthquake and tsunami on 11 March 2011. The affected reactors were adjacent to one another and accident management was made much more difficult because of ...

  5. Fukushima nuclear accident - Wikipedia

    en.wikipedia.org/wiki/Fukushima_nuclear_accident

    The Fukushima nuclear accident was a major nuclear accident at the Fukushima Daiichi Nuclear Power Plant in Ōkuma, Fukushima, Japan, which began on 11 March 2011. The proximate cause of the accident was the 2011 Tōhoku earthquake and tsunami , which resulted in electrical grid failure and damaged nearly all of the power plant's backup energy ...

  6. Fukushima nuclear accident (Unit 3 Reactor) - Wikipedia

    en.wikipedia.org/wiki/Fukushima_nuclear_accident...

    On 11 May, TEPCO released underwater robotic video from the spent fuel pool. The video appears to show large amounts of debris contaminating the pool. Based on water samples analysed, unnamed experts and TEPCO reported that the fuel rods were left "largely undamaged", [ 51 ] [ 52 ] and that it appears that the Unit 3 explosion was entirely ...

  7. Containment building - Wikipedia

    en.wikipedia.org/wiki/Containment_building

    The containment isolation valves may also close on a variety of other signals such as the containment high pressure experienced during a high-energy line break (e.g. main steam or feedwater lines). The containment building serves to contain the steam/resultant pressure, but there is typically no radiological consequences associated with such a ...

  8. Economic Simplified Boiling Water Reactor - Wikipedia

    en.wikipedia.org/wiki/Economic_Simplified...

    In events where the reactor coolant pressure boundary remains intact, the Isolation Condenser System (ICS) is used to remove decay heat from the reactor and transfer it outside containment. The ICS system is a closed loop system that connects the reactor pressure vessel to a heat exchanger located in the upper elevation of the reactor building.

  9. Timeline of the Fukushima nuclear accident - Wikipedia

    en.wikipedia.org/wiki/Timeline_of_the_Fukushima...

    Only the steam-powered pump systems (isolation condenser in reactor 1, high-pressure coolant injection and reactor core isolation cooling system in reactors 2 and 3) remained available. Later, as the temperature rose, a system started that used steam-powered pumps [failed verification] and battery-powered valves. [9] [10]