  1. Results From The WOW.Com Content Network
  2. Ventricular escape beat - Wikipedia

    en.wikipedia.org/wiki/Ventricular_escape_beat

    If the rate from both the SA and AV node fall below the discharge rate of ventricular pacemaker cells, a ventricular escape beat ensues. [citation needed] An escape beat is a form of cardiac arrhythmia, in this case known as an ectopic beat. It can be considered a form of ectopic pacemaker activity that is unveiled by lack of other pacemakers ...

  3. Junctional rhythm - Wikipedia

    en.wikipedia.org/wiki/Junctional_rhythm

    The first finding is that junctional rhythms are regular rhythms. This means that the time interval between beats stays constant. The next normal finding is a normal QRS. Since the impulse still travels down the bundle of His, the QRS will not be wide. Junctional rhythms can present with either bradycardia, a normal heart rate, or tachycardia. [9]

  4. Cardiac pacemaker - Wikipedia

    en.wikipedia.org/wiki/Cardiac_pacemaker

    It employs pacemaker cells that produce electrical impulses, known as cardiac action potentials, which control the rate of contraction of the cardiac muscle, that is, the heart rate. In most humans, these cells are concentrated in the sinoatrial (SA) node , the primary pacemaker, which regulates the heart’s sinus rhythm .

  5. Third-degree atrioventricular block - Wikipedia

    en.wikipedia.org/wiki/Third-degree_atrio...

    This is typically extensive, permanent damage to the conduction system, eliciting a necessity for a permanent pacemaker to be placed. [6] The escape rhythm typically originates in the ventricles, producing a wide complex escape rhythm. Third-degree heart block may also be congenital and has been linked to the presence of lupus in the mother. [7]

  6. Sinoatrial arrest - Wikipedia

    en.wikipedia.org/wiki/Sinoatrial_arrest

    Atrial escape (rate 60–80): originates within atria, not sinus node (normal P morphology is lost). Junctional escape (rate 40–60): originates near the AV node; a normal P wave is not seen, may occasionally see a retrograde P wave. Ventricular escape (rate 20–40): originates in ventricular conduction system; no P wave, wide, abnormal QRS.

  7. Bradycardia - Wikipedia

    en.wikipedia.org/wiki/Bradycardia

    Bradycardia, also called bradyarrhythmia, is a resting heart rate under 60 beats per minute (BPM). [1] While bradycardia can result from various pathologic processes, it is commonly a physiologic response to cardiovascular conditioning or due to asymptomatic type 1 atrioventricular block.

  8. AOL Mail

    mail.aol.com

    Get AOL Mail for FREE! Manage your email like never before with travel, photo & document views. Personalize your inbox with themes & tabs. You've Got Mail!

  9. Pacemaker - Wikipedia

    en.wikipedia.org/wiki/Pacemaker

    A pacemaker, also known as an artificial cardiac pacemaker, is an implanted medical device that generates electrical pulses delivered by electrodes to one or more of the chambers of the heart. Each pulse causes the targeted chamber(s) to contract and pump blood, [3] thus regulating the function of the electrical conduction system of the heart.