  2. OpenTherm - Wikipedia

    en.wikipedia.org/wiki/OpenTherm

    An application example is a room temperature controller connected to a heat recovery unit, which is connected to a boiler. The heat recovery unit is then functioning as gateway. In another possible configuration, a thermostat or room controller is connected to a sequencer with further Opentherm interfaces connected to more than one boiler.

  3. Freeze stat - Wikipedia

    en.wikipedia.org/wiki/Freeze_stat

    When the temperature reaches a specific setpoint, the pressure in the diaphragm will trip a switch which typically shuts down the flow of outside air while the capillary bulb's temperature is at or below the setpoint. [6] Mechanical freeze stats can have more than one set of contacts, and the contacts can be NO or NC. [2] Disadvantages

  4. Central heating - Wikipedia

    en.wikipedia.org/wiki/Central_heating

    This limit controller may shut the furnace off if the blower fails or if something is blocking the air flow. The heated air is then sent back through the home through supply ducts. In larger commercial applications, central heating is provided through an air handler which incorporates similar components as a furnace but on a larger scale.

  5. Hydronics - Wikipedia

    en.wikipedia.org/wiki/Hydronics

    The two-pipe reverse return configuration which is sometimes called 'the three-pipe system' is different from the two-pipe system in the way that water returns to the boiler. In a two-pipe system, once the water has left the first radiator, it returns to the boiler to be reheated, and so with the second and third etc.

  6. Thermostat - Wikipedia

    en.wikipedia.org/wiki/Thermostat

    A thermostat exerts control by switching heating or cooling devices on or off, or by regulating the flow of a heat transfer fluid as needed, to maintain the correct temperature. A thermostat can often be the main control unit for a heating or cooling system, in applications ranging from ambient air control to automotive coolant control.

  7. Heating, ventilation, and air conditioning - Wikipedia

    en.wikipedia.org/wiki/Heating,_ventilation,_and...

    The control system can compare the temperature of the outside air vs. return air, or it can compare the enthalpy of the air, as is frequently done in climates where humidity is more of an issue. In both cases, the outside air must be less energetic than the return air for the system to enter the economizer mode.

  8. Sail switch - Wikipedia

    en.wikipedia.org/wiki/Sail_switch

    A sail switch, vane switch or flow switch is a mechanical switch that is actuated on or off in response to the flow or non-flow of a fluid such as air or water. [1] A sail switch typically operates through the use of a paddle or a diaphragm which gets displaced due to the force of fluid or air moving past it.

  9. Hot water reset - Wikipedia

    en.wikipedia.org/wiki/Hot_water_reset

    A hot water reset control loop measures the outside air temperature; this information is used to estimate demand or heating load as the outdoor temperature varies. The supply hot water temperature is modulated up and down range in an inverse linear ratio to outside air temperature. The typical range for conventional boilers is to vary the ...