A fire test can be conducted to determine the degree of flammability. Test standards used to make this determination but are not limited to the following: Underwriters Laboratories UL 94 Flammability Testing; International Electrotechnical Commission IEC 60707, 60695-11-10 and 60695-11-20; International Organization for Standardization ISO 9772 ...
This test method measures flame growth on the underside of a horizontal test specimen, using the Steiner tunnel test. The result is derivation of a Flame Spread Index ( FSI ), [ 2 ] which is a non-dimensional number which is placed on a relative scale in which asbestos-cement board has a value of 0, and red oak wood has 100.
Construction of a test sample consists of a mockup of a section of concrete floor, with typical mechanical and electrical utility components (pipes and cables) penetrating the floor assembly. A firestop mortar is applied around the penetrations. The completed test sample is inserted into a furnace such that one side is exposed to a fire.
EN 16034 Pedestrian doorsets, industrial, commercial, garage doors and openable windows – Product standard, performance characteristics – Fire resisting and/or smoke control characteristics; FAR 25.853 [a-1] & ASTM E 906 Standard Test Method for Heat and Visible Smoke Release Rates for Materials and Products, also known as the OSU Test
The Steiner tunnel test is a widely used method of testing building interior wall and ceiling finishes for their ability to support and propagate fire, and for their tendency to emit smoke. The test was developed in 1944 by Al Steiner of Underwriters Laboratories , and has been incorporated as a reference into North American standards for ...
UL 94, the Standard for Safety of Flammability of Plastic Materials for Parts in Devices and Appliances testing, is a plastics flammability standard released by Underwriters Laboratories of the United States. [1] The standard determines the material's tendency to either extinguish or spread the flame once the specimen has been ignited.
Workability can be measured by the concrete slump test, a simple measure of the plasticity of a fresh batch of concrete following the ASTM C 143 or EN 12350-2 test standards. Slump is normally measured by filling an "Abrams cone" with a sample from a fresh batch of concrete. The cone is placed with the wide end down onto a level, non-absorptive ...
Maximum experimental safe gap (MESG) is a standardized measurement of how easily a gas flame will pass through a narrow gap bordered by heat-absorbing metal. MESG is used to classify flammable gases for the design and/or selection of electrical equipment in hazardous areas, and flame arrestor devices. [1]