When.com Web Search

  1. Ads

    related to: why do we need ml in science lab analysis calculator

Search results

  1. Results From The WOW.Com Content Network
  2. Sample size determination - Wikipedia

    en.wikipedia.org/wiki/Sample_size_determination

    The table shown on the right can be used in a two-sample t-test to estimate the sample sizes of an experimental group and a control group that are of equal size, that is, the total number of individuals in the trial is twice that of the number given, and the desired significance level is 0.05. [4]

  3. Nucleic acid quantitation - Wikipedia

    en.wikipedia.org/wiki/Nucleic_acid_quantitation

    When using a path length that is shorter than 10mm, the resultant OD will be reduced by a factor of 10/path length. Using the example above with a 3 mm path length, the OD for the 100 μg/mL sample would be reduced to 0.6. To normalize the concentration to a 10mm equivalent, the following is done: 0.6 OD X (10/3) * 50 μg/mL=100 μg/mL

  4. Colony-forming unit - Wikipedia

    en.wikipedia.org/wiki/Colony-forming_unit

    The CFU/plate is read from a plate in the linear range, and then the CFU/g (or CFU/mL) of the original is deduced mathematically, factoring in the amount plated and its dilution factor. A solution of bacteria at an unknown concentration is often serially diluted in order to obtain at least one plate with a countable number of bacteria.

  5. Standard addition - Wikipedia

    en.wikipedia.org/wiki/Standard_addition

    When working with limiting amount of sample, an analyst might need to make a single addition, but it is generally considered a best practice to make at least two additions whenever possible. [5] Note that this is not limited to liquid samples. In atomic absorption spectroscopy, for example, standard additions are often used with solid as the ...

  6. Standard solution - Wikipedia

    en.wikipedia.org/wiki/Standard_solution

    In analytical chemistry, a standard solution (titrant or titrator) is a solution containing an accurately known concentration.Standard solutions are generally prepared by dissolving a solute of known mass into a solvent to a precise volume, or by diluting a solution of known concentration with more solvent. [1]

  7. Titration - Wikipedia

    en.wikipedia.org/wiki/Titration

    Titration (also known as titrimetry [1] and volumetric analysis) is a common laboratory method of quantitative chemical analysis to determine the concentration of an identified analyte (a substance to be analyzed). A reagent, termed the titrant or titrator, [2] is prepared as a standard solution of known concentration and volume.

  8. Virus quantification - Wikipedia

    en.wikipedia.org/wiki/Virus_quantification

    Virus quantification is counting or calculating the number of virus particles (virions) in a sample to determine the virus concentration. It is used in both research and development (R&D) in academic and commercial laboratories as well as in production situations where the quantity of virus at various steps is an important variable that must be monitored.

  9. Bacteriological water analysis - Wikipedia

    en.wikipedia.org/wiki/Bacteriological_water_analysis

    In this method a measured sub-sample (perhaps 10 ml) is diluted with 100 ml of sterile growth medium and an aliquot of 10 ml is then decanted into each of ten tubes. The remaining 10 ml is then diluted again and the process repeated. At the end of 5 dilutions this produces 50 tubes covering the dilution range of 1:10 through to 1:10000.